11.07.2015 Views

Jandy LXi : installation and operation manual - Piscines et Spas ...

Jandy LXi : installation and operation manual - Piscines et Spas ...

Jandy LXi : installation and operation manual - Piscines et Spas ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Page 30<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation ManualNOTE If you need to install more than two wires ineach terminal, order a <strong>J<strong>and</strong>y</strong> Multiplex PCBKit, which includes the Multiplex Board (<strong>J<strong>and</strong>y</strong>part # 6584). Never put more than two wiresinto each of the pins of the terminal bar.5. Check all wiring, then apply power to both theheater <strong>and</strong> the RS control system. Operation canbe verified in either Service or Auto mode. Seeyour RS Control System <strong>manual</strong> for instructionsabout <strong>operation</strong>.When the <strong>LXi</strong> heater is first powered on <strong>and</strong>there is an RS control connected to the heater, thedisplay on the heater control will show "JANDY RE-MOTE ONLINE PUSH MENU TO DISABLE".When the <strong>LXi</strong> heater is online with the RScontrol, all functionality of the control on the heater isdisabled. The heater functions can be controlled onlyat the RS unit.To temporarily use the heater controls, pressthe MENU button. The message "JANDY REMOTEONLINE PUSH MENU TO DISABLE" will disappearfrom the heater display. All functionality has now beenr<strong>et</strong>urned to the control on the heater. In this mode theRS unit is no longer controlling the heater.To r<strong>et</strong>urn the functionality to the RS unit, cycle(turn off <strong>and</strong> then turn on) the power to the heater, orpress the MENU button for 5 seconds to enter the UserS<strong>et</strong>up Mode <strong>and</strong> then enable the <strong>J<strong>and</strong>y</strong> Remote.6.5.3 Connection to a Secondary UseInterfaceThe <strong>LXi</strong> pool/spa heater can also be controlledremotely by installing a second wall mountable UserInterface. Please order <strong>J<strong>and</strong>y</strong> part number R0467500.This kit contains the second User Interface, wallmounting backplate, <strong>and</strong> necessary hardware.Section 7. Operating Instructions7.1 Normal OperationThe <strong>LXi</strong> heater is capable of automatic <strong>operation</strong>based on a call for heat at pres<strong>et</strong> temperatures <strong>and</strong>an operator selection b<strong>et</strong>ween pool or spa s<strong>et</strong>tings.Additionally, the heater may be controlled by a remoteunit to anticipate bather load, changes in temperatures<strong>et</strong>tings, or a vari<strong>et</strong>y of other dem<strong>and</strong>s that might beencountered. The heater has an internal saf<strong>et</strong>y systemwhich allows <strong>operation</strong> in a vari<strong>et</strong>y of conditions <strong>and</strong>prevents <strong>operation</strong> when certain adverse conditions areencountered. The heater is capable of diagnosing problemswithin the saf<strong>et</strong>y controls scheme, enabling fasterservice <strong>and</strong> less down time in the event of a failure.When the heater is powered, water is flowingthrough the heater, <strong>and</strong> the temperature of the waterentering the heater is below the temperature controls<strong>et</strong>ting, an operating cycle is initiated by the automaticcontrol. The combustion blower is started. If theblower pressure switch senses adequate airflow, the ignitionsequence starts. First, a fifteen second pre-purg<strong>et</strong>akes place. Next, the igniter is energized. After 40seconds of igniter heat-up time the gas valve is opened(approximately one minute after the call for heat). Ifflame is sensed at the burner within seven seconds,<strong>operation</strong> continues. Operation will continue until th<strong>et</strong>emperature of the water entering the heater reachesthe temperature control s<strong>et</strong>ting.If ignition is unsuccessful, or if the flame failsduring normal <strong>operation</strong>, the ignition control shuts offthe gas valve. It imposes a post purge, initiates additionalignition cycles, <strong>and</strong> shuts down the system ifignition is not achieved in three cycles. After one hour,the system will restart <strong>and</strong> try again.To res<strong>et</strong> the <strong>LXi</strong> heater to provide three (3) additionalattempts without waiting an hour, turn off thecontrol <strong>and</strong> then put it back in either the Pool or Spamode.7.2 Start-UpWARNINGFor your saf<strong>et</strong>y, when starting the heater, keep yourhead <strong>and</strong> face well away from the burner area toprevent any risk of personal injury.AVERTISSEMENTPour votre sécurité personnelle lorsque vous m<strong>et</strong>tezl’appareil en marche, tenez votre tête <strong>et</strong> votre visageloin du brûleur pour éviter tout risque de blessure.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!