11.07.2015 Views

Jandy LXi : installation and operation manual - Piscines et Spas ...

Jandy LXi : installation and operation manual - Piscines et Spas ...

Jandy LXi : installation and operation manual - Piscines et Spas ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation Manual Page 13Notes:1. Use approvedroof jack.3)Figure 7. Indoor Installation Venting (USA), or Outdoor Shelter (Canada)Table 3. Air Openings to OutsideRequired N<strong>et</strong> Free Open Area*for Combustion Air OpeningsModelDirect from outside Duct from outsidein 2 (cm 2 ) in 2 (cm 2 )250 63 (406) 126 (813)300 75 (484) 150 (968)400 100 (645) 200 (1290)*Area indicated is for one of two openings; one at fl oor level <strong>and</strong>one at the ceiling, so the total n<strong>et</strong> free area would be double thefi gures indicated. For special conditions, refer to NFPA54 ANSIZ223.1. In Canada refer to the National St<strong>and</strong>ard CAN/CSA-B149.1 which differs from this table.Note: If using screens <strong>and</strong>/or m<strong>et</strong>al louvers, compensate by adding50% additional area to each opening. If using wood louvers each openingmust be at least four times the area indicated in the table above.Exhaust Fans or Vents: Any equipmentwhich exhausts air from the room where the heateris installed can depl<strong>et</strong>e the combustion air supply orreverse the natural draft action of the venting system.This could cause flue products to accumulate in theroom. Additional air must be supplied to compensatefor such exhaust.The information in Table 3 is not applicable in<strong>installation</strong>s where exhaust fans or blowers of any typeare used. Such <strong>installation</strong>s must be designed by qualifiedengineers.The heater must be compl<strong>et</strong>ely isolated <strong>and</strong>protected from any source of corrosive chemical fumessuch as those emitted by trichlor<strong>et</strong>hylene, perchloro<strong>et</strong>hylene,chlorine, <strong>et</strong>c.WARNINGDo not store any chemicals, cleaners, or other corrosivematerial near combustion air openings or inthe room. Avoid locating appliance vents in the vicinityof combustion air openings. Failure to preventcorrosive materials from mixing with combustion aircan result in reduced heater life <strong>and</strong> unsafe heater<strong>operation</strong>.AVERTISSEMENTNe pas entreposer ni utiliser d'essence ni d'autresvapeurs ou liquides infl ammables à proximité de c<strong>et</strong>appareil ou de tout autre appareil.3.2 Exhaust VentingWhen converted to indoor <strong>and</strong> outdoor shelterventing configuration, the <strong>LXi</strong> heater has a vent collarfitting for attachment to the venting. The diam<strong>et</strong>er ofthe vent collar <strong>and</strong>, thus, the minimum diam<strong>et</strong>er ofthe vent pipe to be used is d<strong>et</strong>ermined by the modelof heater installed <strong>and</strong> the type of venting. The onlycorrect procedure for vent pipe sizing is to do so inaccordance with Table 4 <strong>and</strong> the applicable <strong>installation</strong>code as stated in the following "Danger" warning.Note that with horizontal Category III type vent<strong>installation</strong>s, the venting may be smaller than the ventcollar for Category I vertical venting. See Table 4.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!