Page 26<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation Manual<strong>J<strong>and</strong>y</strong> Pool Products, Inc., requires that the appliancebe connected to a “bonding loop” that includes allelectrical equipment in the system <strong>and</strong> on the equipmentpad. Bonding lugs must be connected with asolid copper wire not smaller than 8 AWG (6 AWG inCanada). Failure to do so will void the <strong>J<strong>and</strong>y</strong> warranty.Additionally, in the United States the NationalElectrical Code (NEC) <strong>and</strong> in Canada the CanadianElectrical Code (CEC), require that all m<strong>et</strong>alliccomponents of a pool structure, including reinforcingsteel, m<strong>et</strong>al fittings <strong>and</strong> above ground components bebonded tog<strong>et</strong>her (forming an “equipotential bondinggrid”) with a solid copper conductor not smaller thanan 8 AWG (6 AWG in Canada).The NEC <strong>and</strong> CEC also require that the equipment<strong>and</strong>/or appliances associated with the pool watercirculating system, including, but not limited to, pumpmotors <strong>and</strong> heaters, be bonded tog<strong>et</strong>her as part of theequipotential bonding grid. <strong>J<strong>and</strong>y</strong> provides a speciallabeled bonding lug on the right side of the heater toaccommodate this requirement.6.4 Optional Pump Connection(Maintain Temp Feature)This optional feature allows the heater to turnon the pool pump, bypassing the time clock s<strong>et</strong>ting,to maintain the desired temperature. In order for theMAINTAIN TEMP feature to be functional, a relaymust be installed <strong>and</strong> a dedicated line from the poolpump time clock to the Maintain Temp (Pump) Relayis needed. See Figure 24. The relay <strong>and</strong> pertinentinstructions can be obtained by ordering <strong>J<strong>and</strong>y</strong> partnumber R0467200.6.5 Optional Remote ControlsWARNINGRISK OF ELECTRIC SHOCK WHICH CAN RE-SULT IN SERIOUS INJURY OR DEATH. Beforeattempting <strong>installation</strong> or service, ensure that allpower to the device is disconnected/turned off at thecircuit breaker.AVERTISSEMENTRISQUE DE CHOC ÉLECTRIQUE POUVANTCAUSER DES BLESSURES GRAVES OU LAMORT. Avant de tenter l’<strong>installation</strong> ou d’utiliser leservice, assurez-vous que l’alimentation allant versle dispositif soit débranchée/éteinte au niveau dudisjoncteur du circuit. Branchez seulement à uncircuit protégé par un disjoncteur de mise à la terre.Electrical wiring must be in accordance with thelatest edition of the National Electric Code (NEC),ANSI/National Fire Protection Association (NFPA) 70,unless local code requirements indicate otherwise.INTERMATIC MODEL T104 MECHANICAL TIMER(NOT PROVIDED WITH HEATER)4EQUIPMENTGROUNDCLOCKMOTOR123L2L1240 VAC PUMPFIELD INSTALLED COMPONENTSOPTIONAL HEATER COMPONENTSNOTE:MAINTAIN TEMP (PUMP) RELAY(SEE HEATER WIRING DIAGRAM)INTERMATIC MODEL T104 (NOT PROVIDED WITH HEATER) WIRE CONNECTIONS SHOWN AS AN EXAMPLE,OTHER MODELS MAY HAVE DIFFERENT CONNECTIONS. CONSULT TIMER MANUFACTURER FOR PROPER CONNECTIONS.Figure 24. Example of Maintain Temp Wiring to the Time Clock

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!