Page 36<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation ManualMake sure the pool filter is clean before makingany pressure switch adjustment. A dirty filter willrestrict the water flow <strong>and</strong> the pressure switch cannot beadjusted properly.To adjust the pressure switch, refer to Figure 31<strong>and</strong> proceed as follows:BYPASSADJUSTMENTSCREW1. S<strong>et</strong> the heater control to the "OFF" mode.2. Remove the side panel above the front header toaccess the water pressure switch.3. Start the filter pump <strong>and</strong> confirm by means of avoltm<strong>et</strong>er that the pressure switch closes (if theswitch fails to close, replace it with a switch thathas a lower minimum s<strong>et</strong>ting).4. S<strong>et</strong> the heater control to either POOL or SPA.Heater should start.5. Pry out the top cap on the pressure switch.6. Use a 7/32" Allen wrench to turn the adjustmentscrew very slowly clockwise until the heater goesoff.7. Slowly turn the pressure switch adjustment screwcounterclockwise one-quarter turn. The heatershould come back on.8. Check the adjustment by turning the filter pumpOFF. The heater fan will continue to run but theburners should shut off immediately. If they donot, restart the filter pump <strong>and</strong> repeatSteps 6 <strong>and</strong> 7. Check the adjustment again.9. R<strong>et</strong>urn the pool temperature control to the desiredtemperature.It may be necessary to repeat these steps to g<strong>et</strong> aproper s<strong>et</strong>ting. The switch must be s<strong>et</strong> so that the heaterwill not fire unless the pump is running. If a propers<strong>et</strong>ting cannot be reached, contact the factory servicedepartment.7.8 Temperature RiseThe <strong>LXi</strong> pool <strong>and</strong> spa heaters have an internal bypasswhich accommodates a wide range of water flow.The bypass is easily adjustable to change the temperaturerise for optimum performance <strong>and</strong> length of heaterlife. The bypass assures constant heat exchanger floweven though flow through the filter system will varydepending on how dirty the filter is.For most <strong>installation</strong>s, an external bypass valveis not needed in the heater water piping. This is due tothe large size of the heater's internal bypass valve. If thepump flow rate is known to exceed 125 gpm(7.9 l/s), an external bypass may be needed to assureproper heater <strong>operation</strong>.THERMOMETER WITHPETE'S PLUG ®Figure 32. Temperature Rise MeasurementWater flow should be confirmed upon start-up ofthe heater <strong>and</strong> in most servicing situations. If the flowis not normal, corrections must be made to the poolsystem. Flow is evaluated by d<strong>et</strong>ermining the watertemperature rise through the heat exchanger.Before checking the temperature rise, make sur<strong>et</strong>hat the pool filter is clean <strong>and</strong> that gas supply <strong>and</strong>manifold pressures are correct. If necessary, clean allcomponents of the filter system. Temperature rise ismeasured in the r<strong>et</strong>urn header of the <strong>LXi</strong>. To measur<strong>et</strong>he temperature rise, turn off the filter pump <strong>and</strong>remove the plastic plug protruding through the cabin<strong>et</strong>on the r<strong>et</strong>urn header side of the heater. (See Figure32.) With the plug removed, install the special threadadapter <strong>and</strong> P<strong>et</strong>e’s Plug ® fitting <strong>and</strong> insert a pock<strong>et</strong>thermom<strong>et</strong>er. A temperature rise measurement kit isavailable through your <strong>J<strong>and</strong>y</strong> distributor. See Section11 of this <strong>manual</strong> for the correct kit number.P<strong>et</strong>e's Plug ® is a registered trademark of the P<strong>et</strong>erson EquipmentCompany.The internal bypass can be adjusted by means ofa screw on the right-h<strong>and</strong> side of the header. To adjustthe temperature rise to within the ranges specified inTable 7, proceed as follows:1. If the piping system has an external bypass valve,close it.2. S<strong>et</strong> the heater's control panel to the "OFF" position.3. Start the filter pump.4. After three minutes, note <strong>and</strong> record the thermom<strong>et</strong>erreading. This is the pool water temperature.5. Start the heater by s<strong>et</strong>ting the control panel toeither POOL or SPA. Allow the heater to operatefor 5 minutes or more. Note <strong>and</strong> record the thermom<strong>et</strong>erreading. Subtract pool water tempera-

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!