11.07.2015 Views

ACCLAIM oa - Cromlab

ACCLAIM oa - Cromlab

ACCLAIM oa - Cromlab

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Acclaim OAIsocratic Separation of Hydrophilic Organic AcidsRuggedness Test at pH 2.680.025AU021 3 45 6 7 8 91011120 5 10 15MinutesColumn: Acclaim OA, 5 µmDimensions: 4 × 250 mmMobile Phase: 100 mM Na 2 SO 4 , pH 2.65 (adjustedwith methanesulfonic acid)Temperature: 30 °CFlow Rate: 0.6 mL/minInj. Volume: 5 µLDetection: UV, 210 nmPeaks: 1. Oxalic acid 15 mg/L (ppm)2. Tartaric acid 1203. Formic acid 1804. Malic acid 1205. iso-Citric acid 1206. Lactic acid 1807. Acetic acid 1208. Citric acid 1209. Succinic acid 12010. Fumaric acid 711. cis-Aconitic acid **12. trans-Aconitic acid **** 7 ppm total for cis and trans isomers20011AU021 3 4 85 6 7291011 121013 485 6 7 9 11 122Injection 1Injection 10894 6 8MinutesColumn: Acclaim OA, 5 µmDimensions: 4 × 150 mmMobile Phase: 40 mM Na 2 SO 4 , pH(adjusted with methanesulfonic acid)Temperature: 30 °CFlow Rate: 1.0 mL/minInj. Volume: 5 µLDetection: UV, 210 nmPeaks: 1. Oxalic acid 15 mg/L (ppm)2. Tartaric acid 1203. Formic acid 1804. Malic acid 1205. iso-Citric acid 1206. Lactic acid 1807. Acetic acid 1208. Citric acid 1209. Succinic acid 12010. Fumaric acid 311. cis-Aconitic acid**12. trans-Aconitic acid*** *3 ppm total for cis andtrans isomers20012Gradient Separation of C1–C7 Aliphatic Organic Acids0.1800.100AU01234, 5Minutes6789 100 5 10 15 20Column: Acclaim OA, 5 µmDimensions: 4 × 250 mmMobile Phases: A: CH 3CNB: 2.5 mM methanesulfonic acidGradient: -10 0 1 15 20 min.2 2 2 60 60 %A98 98 98 40 40 %BTemperature: 30 °CFlow Rate: 1.0 mL/minInj. Volume: 30 µLDetection: UV, 210 nm with blank subtractionPeaks: 1. Formic acid 10 mmol/L2. Acetic acid 103. Propionic acid 104. Butyric acid 105. Isobutyric acid 106. Isovaleric acid 107. n-Valeric acid 108. Isocaproic acid 109. n-Caproic acid 1010. Heptanoic acid 10OA23611Ordering Information: Acclaim OAThe standard particle size is nominally 5 µm. Analytical columns are available in 4.0-mm diameters; standard lengths are 150 and 250 mm.Guard cartridges in 4.3 × 10 mm are recommended to protect your analytical columns. Other geometries in PEEK or stainless steel areavailable; inquire with your Dionex sales representative.Please order through your local Dionex office or distributor. Refer to the following part numbers.Acclaim OA Analytical Columns5 µm 4.0 × 150 mm ............................... 0629035 µm 4.0 × 250 mm ............................... 062902Acclaim OA Guard Columns5 µm 4.3 × 10 mm . ...............................062925Biocompatible cartridge holder for2.1 × 10 mm and 4.3 × 10 mm guards ..................059456Guard to analytical column coupler ...................059457Holder and coupler kit. ..............................059526These columns are designed for optimal performance using Dionex UltiMate 3000 and ICS-3000 chromatography instruments.www.dionex.com - 23 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!