11.07.2015 Views

ultima ultra multi-temp ultra xl extra optima with standard micro prior ...

ultima ultra multi-temp ultra xl extra optima with standard micro prior ...

ultima ultra multi-temp ultra xl extra optima with standard micro prior ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

. Perishable Cooling Unloader ControlDieselDuring perishable cooling the unloaders are energizedwhen the <strong>temp</strong>erature approaches setpoint. If a supplyprobeispresenttheunloadersareenergizedwhenthesupply <strong>temp</strong>erature decreases 5.4_F (3_C) belowsetpoint. It will stay unloaded until the supply<strong>temp</strong>erature rises above setpoint. If a supply probe is notpresent the unloaders are energized when the return<strong>temp</strong>erature decreases more than 9_F (5_C) abovesetpoint. It will stay unloaded until the return<strong>temp</strong>erature rises more than 14.4_F (8_C) abovesetpoint. With software revision 2.10 or higher the returnprobe logic is disabled for ambient <strong>temp</strong>erature higherthan 90_F (32.2_C).StandbyDuring perishable cooling the unloaders are energizedwhen the control <strong>temp</strong>erature reaches less than 2_F(1.1_C) above setpoint. The unloaders stay energizeduntil the control <strong>temp</strong>erature reaches 2.5_F (1.4_C)above setpoint.c. Perishable Heating Unloader ControlDieselDuring perishable heating the front unloader isenergized when the control <strong>temp</strong>erature increases to0.9_F (0.5_C) below setpoint. The unloader will stayenergized until the control <strong>temp</strong>erature decreases to1.5_F (0.8_C) below setpoint.Note: These switch points may vary slightly dependingonthe amount of overshoot around setpoint.StandbyDuring perishable heating the unloaders are energizedwhen the control <strong>temp</strong>erature increases to 1.5_F (0.8_C)below setpoint. The unloaders will stay energized until thecontrol <strong>temp</strong>erature decreases to 2_F (1.1_C) belowsetpoint.Note: During standby operation the unit may energizeboth the front and rear unloaders in heat(2 cylinders).d. Frozen Unloader ControlDieselFor units <strong>with</strong> UltraFreeze refer to section 1.13.For units <strong>with</strong>out UltraFreeze during frozen mode,heating is not allowed. The front unloader is energizedwhen the control <strong>temp</strong>erature decreases to 1.5_F (0.8_C)above setpoint. The unloader will stay energized untilthecontrol <strong>temp</strong>erature reaches 2_F (1.1_C) above setpoint.Note: During frozen mode only the front cylinder can beunloaded.StandbyFor units <strong>with</strong> UltraFreeze refer to section 1.13.For units <strong>with</strong>out UltraFreeze during frozen mode,heating is not allowed. The front unloader is energizedwhen the control <strong>temp</strong>erature decreases to 2_F (1.1_C)above setpoint. The unloader will stay energized until thecontrol <strong>temp</strong>erature reaches 2.5_F (1.4_C) abovesetpoint.1.9.2 Suction Pressure Operation - Diesel EngineThe <strong>micro</strong>processor will monitor suction pressure of therefrigeration system and control the unloaders tomaintain a maximum operating pressure. A suction9pressure transducer is used to signal the <strong>micro</strong>processorwhen to load or unload the compressor.When the compressor is fully loaded it is operating on 6cylinders. When the front unloader UL1 is unloaded(energized), the unit operates on 4 cylinders. When UL1and the rear unloader UL2 are unloaded (energized), theunit operates on 2 cylinders. The front unloader, UL1,always unloades before the rear unloader, UL2.During the diesel heating and defrosting cycles, the rearunloader is locked out (loaded), forcing the compressorto always operate <strong>with</strong> at least four cylinders loaded.a. R-22 Refrigeration SystemAt ambient <strong>temp</strong>eratures of 90_F (32.2_C) or belowWhen the system is operating in high speed and thesuction pressure is greater than 53 psig, both unloadersare unloaded. As the suction pressure drops below 52psig, the UL2 unloader is loaded. If the suction pressuredrops below 26 psig, the UL1 unloader is loaded.When the system is operating in low speed and the suctionpressure is greater than 56 psig, both unloaders areunloaded. As the suction pressure drops below 55 psig,the UL2 unloader is loaded. If the suction pressure dropsbelow 21 psig, the UL1 unloader is loaded.At ambient <strong>temp</strong>eratures of 90_F (32.2_C) or higherAt ambient <strong>temp</strong>eratures of 90_F or higher the unloadingsuction pressure settings relative to ambient<strong>temp</strong>eratures are a straight line.(Refer to chart below)SUCTIONPRESSURE(PSIG)R-22 DIESEL OPERATIONSUCTION PRESSURE UNLOADING60LOW SPEED (UL2)55504540353025HIGHSPEED(UL2)HIGH SPEED (UL1)20LOW15 SPEED10(UL1)80 90 100 110 120 130AMBIENT TEMPERATURE (_F)UL1 = FRONT UNLOADER, UL2 = REAR UNLOADERABOVE THE LINE = UNLOADED, BELOW THE LINE = LOADEDb. R-404A Refrigeration SystemAt ambient <strong>temp</strong>eratures of 90_F (32.2_C) or belowWhen the system is operating in high speed and thesuction pressure is greater than 64 psig, both unloadersare unloaded. As the suction pressure drops below 64psig, the UL2 unloader is loaded. If the suction pressuredrops below 33 psig, the UL1 unloader is loaded.1-15 62-02461

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!