1.1.1 HEAT/COOL MODE1.10.7ALARM DISPLAYThe fault light (FL) is turned on only for alarms thatspecify it. The default display will be overridden if a alarmis generated. When an alarm is generated, the display willalternate the default display (setpoint/air <strong>temp</strong>erature)and the active alarm(s). Each item will be displayed for 3to 10 seconds, and will continue to scroll through the list.See section 1.10.5 for the procedure on resetting alarms.Table 1-7. Alarm DisplayCODE ENGLISH ALARM DESCRIPTIONAL0 ENG OIL Low Oil PressureAL1 ENG HOTHigh CoolantTemperatureAL2 HI PRESS High PressureAL3 STARTFAIL Auto Start FailureAL4 LOW BATT Low Battery VoltageAL5 HI BATT High Battery VoltageAL6 DEFRFAIL Defrost OverrideAL7 ALT AUX Alternator AuxiliaryAL8 STARTER Starter MotorAL9 RA SENSOR Return Air SensorAL10 SA SENSOR Supply Air SensorAL11WT SEN-SORAL12 HIGH CDTAL13 CD SENSORAL14SBY MO-TORCoolant TemperatureSensorHigh DischargeTemperatureDischarge TemperatureSensorMotor OverloadAL15 FUSE BAD FuseAL17 DISPLAY DisplayAL18 SERVICE 1 Maintenance Hour Meter 1AL19 SERVICE 2 Maintenance Hour Meter 2AL20OUTRANGEMain CompartmentOut-of-rangeAL21 2RA OUT Remote Compartment 2Out-of-rangeAL22 3RA OUT Remote Compartment 3Out-of-rangeAL23 CLUTCH Clutch Failure =FAULTLIGHTONLow Oil Pressure AlarmThe low oil pressure alarm is displayed <strong>with</strong> thedescription ENG OIL or AL0. This alarm is generated ifthe control senses low oil pressure under the properconditions. The fault light (FL) is turned on. Engine willshut down.High Coolant Temperature AlarmThe high coolant <strong>temp</strong>erature alarm is displayed <strong>with</strong> thedescription ENG HOT or AL1. This alarm is generated ifthe control senses a high coolant <strong>temp</strong>erature 230 to240_F (110 to 116_C) for 5 minutes or immediately ifover 240_F (116_C). The fault light (FL) is turned on andengine will shut down.High Pressure AlarmThe high pressure alarm is displayed <strong>with</strong> the descriptionHI PRESS or AL2. This alarm is generated if the highpressure switch opens. The fault light (FL) is turned onand engine will shut down.Start Failure AlarmThe start failure alarm is displayed <strong>with</strong> the descriptionSTARTFAIL or AL3. This alarm is generated if theengine fails to start. The fault light (FL) is turned on.If function MAN OP (manual start mode) is selected thestart failure alarm will be generated if the engine fails tostart in 5 minutes.Low Battery Voltage AlarmThe low battery voltage alarm is displayed <strong>with</strong> thedescription LOW BATT or AL4. This alarm is generatedif the battery voltage falls below 10 vdc. The fault light(FL) is turned on and engine will shut down.High Battery Voltage AlarmThe high battery voltage alarm is displayed <strong>with</strong> thedescription HI BATT or AL5. This alarm is generated ifthe battery voltage is above 17 vdc. The fault light (FL) isturned on and engine will shut down.Defrost Override AlarmThe defrost override alarm is displayed <strong>with</strong> thedescription DEFR FAIL or AL6. This alarm is generatedif the unit is in a defrost override mode (See Section1.10.10).Alternator Auxiliary AlarmThe alternator auxiliary alarm is displayed <strong>with</strong> thedescription ALT AUX or AL7. This alarm is generated ifthe alternator auxiliary signal is not present <strong>with</strong> theengine running. (See Section 1.10.11) The fault light (FL)is turned on.Starter Motor AlarmThe starter motor alarm is displayed <strong>with</strong> the descriptionSTARTER or AL8. This alarm is generated if the startermotor input signal is not present <strong>with</strong> starter solenoidenergized. The fault light (FL) is turned on.ReturnAirSensorAlarmThe return air sensor alarm is displayed <strong>with</strong> thedescription RA SENSOR or AL9. This alarm isgenerated if the return air sensor is open or shorted. Thefault light (FL) is turned on if the unit shuts down becausethere is no controlling probe.Supply Air Sensor AlarmThe supply air sensor alarm is displayed <strong>with</strong> thedescription SA SENSOR or AL10. This alarm isgenerated if the supply air sensor is open or shorted. Thisalarm will be disabled if the REM PROBE is selected inthe controlling probe functional parameter.62-024611-24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!