Select Reod Modified from Position (RMP) Command: Select RMP is an immediatecommand. A Select RMP command is executed by recording the Read Modifiedcondition and returning <strong>Device</strong> End.<strong>The</strong> commands following the Select RMP command should be a chained Writecommand followed by a chained Read Modified command. <strong>The</strong> Write Commandcontains only four bytes (WCC, SBA xx) to set the buffer address. If the sequenceis other than as described, the command will not be accepted, and Channel End,<strong>Device</strong> End, <strong>Unit</strong> Check, Operation Check will be sent to the host.Upon receipt <strong>of</strong> the Write command, the <strong>IBM</strong> <strong>7171</strong> will perform the Read Modifiedfrom Position preparation, and return <strong>Device</strong> End to the host when the datastream is completed. <strong>The</strong> Read Modified command is then executed.Select Reod Buffer from Position (RBP) Command: Select RBP is an immediatecommand. A Select RBP command is executed by recording the Read Buffer conditionand returning <strong>Device</strong> End.<strong>The</strong> commands following the Select RBP command should be a chained Writecommand followed by a chained Read Buffer command. <strong>The</strong> Write command containsonly four bytes (WCC, SBA xx) to set the buffer address. If the sequence isother than as described, the command will not be accepted, and Channel End,<strong>Device</strong> End, <strong>Unit</strong> Check, Operation Check will be sent to the host.Upon receipt <strong>of</strong> the Write command, the <strong>IBM</strong> <strong>7171</strong> will perform the Read Bufferfrom Position preparation, and return <strong>Device</strong> End to the host when the data streamis completed. <strong>The</strong> Read Buffer command is then executed.Select Write Command: Select WRT is an immediate command. A Select WRTcommand is executed by returning <strong>Device</strong> End to the host. If the chainedcommand following the Select WRT is not a Write command, then Channel End,<strong>Device</strong> End, <strong>Unit</strong> Check, Operation Check will be sent to the host.Erose All Unprotected Command: This command performs five functions at theaddressed device:1. Clears all unprotected buffer character locations to nulls.2. Resets to 0 the MDT bit for each unprotected field.3. Always unlocks the keyboard.4. Resets the AID byte.5. Repositions the cursor to the first character location in the first unprotectedfield <strong>of</strong> the buffer. If no unprotected fields exist, the cursor is positioned tobuffer location O.Erase All Unprotected is an immediate type command. Upon acceptance <strong>of</strong> thiscommand, the <strong>IBM</strong> <strong>7171</strong> becomes Busy and sends Channel End initial status to thechannel. Upon successful completion <strong>of</strong> this command, the control unit sends<strong>Device</strong> End status asynchronously to the channel and then becomes Not Busy.Chapter 6. <strong>IBM</strong> <strong>7171</strong> II 0 Interface to the Host System 6-1 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!