Terminal Type Specification ErrorsF-2: Garbled data at terminal screen, Double characters echoed.Line speed and/or line control parameters are inconsistent with attached device.<strong>The</strong> line control parameters the port is initialized with, must be consistent with theattached device. <strong>The</strong> <strong>IBM</strong> <strong>7171</strong> is shipped with the following default line controlparameters defined for all ports.Port 0 is reset to these settings when the <strong>IBM</strong> <strong>7171</strong> is powered on, or receives achannel reset.Seven data bits (7)Even parityOne stop bit<strong>The</strong> 'line control parameters' must be consistent with those <strong>of</strong> the attached device.Reference the documentation (for attached device) for details on checking or modifyingthe line control parameter s.Verify that the attached device is configured for RS-232-C, asynchronous, fullduplex operation. (Half-Duplex configuration may cause double character echo foreach key depressed.) To confirm and/or modify the <strong>IBM</strong> <strong>7171</strong> line control parameters,refer to section 9.8, "C - Configure <strong>IBM</strong> <strong>7171</strong> Ports" on page 9-7 <strong>of</strong> thismanual.If no device type is specified for a terminal in Non-Volatile RAM (NV-RAM), the<strong>IBM</strong> <strong>7171</strong> assumes that the device is a terminal, and requests the terminal typefrom the user. If the wrong type (one that does not match the terminal) is enteredeven though it is a valid terminal type, the <strong>IBM</strong> <strong>7171</strong> will use the wrong TerminalDefinition Table. This will probably result in the terminal malfunctioning.To correct this situation, press the "Return to ENTER TERMINAL TYPEMessage:" key as described in "Return to 'ENTER TERMINAL TYPE:' Message"on page 3-10.If the user cannot get back to the "ENTER TERMINAL TYPE:" message viaentries at the keyboard, he must cause the <strong>IBM</strong> <strong>7171</strong> to restart the communicationline. This can be done for a locally attached terminal by powering the terminal <strong>of</strong>f.For remotely connected lines, intervening communications equipment (modems,port selectors, etc.) may prevent proper restart when the terminal is powered onand <strong>of</strong>f.Under no circumstances will the MASTER RESET function defined in section3.1.7, "Local Reset and <strong>Control</strong> Facilities" on page 3-10 be useful in recoveringfrom an incorrectly chosen terminal type table.8 -4 <strong>IBM</strong> <strong>7171</strong> Reference Manual and Programming Guide,

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!