12.07.2015 Views

2.2 The IBM 7171 ASCII Device Attachment Control Unit - Index of

2.2 The IBM 7171 ASCII Device Attachment Control Unit - Index of

2.2 The IBM 7171 ASCII Device Attachment Control Unit - Index of

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INVALID BAUD RATE<strong>7171</strong> TERM This error message appears when a baud rate is entered which isnot one <strong>of</strong> the allowable values. <strong>The</strong> valid baud rates are listed on the Configure<strong>7171</strong> Ports screen.INV ALID TERMTYPE: xxxxxxxx<strong>IBM</strong> <strong>7171</strong> TERM This error message appears when the terminal namexxxxxxxx is not found in the TERMTYPS list in the Image file which wasloaded. Refer to the Link output listing for the list <strong>of</strong> valid terminal types.NO TERMINAL NAMES IN IMAGE<strong>7171</strong>PORT This error message appears when a file is either not an Image file(wrong file loaded) or is the output <strong>of</strong> a bad link. If this is output from aTML Link, there is no TERMTYPS statement in the TML source.NO TERMTYPS FOUND - IS YOUR CONTROL FILE EMPTY? *<strong>7171</strong>LINK This error message (not a prompt) appears when there are noterminal tables specified in the input control file. Re-edit the control file andthen relink.ONE OR MORE PARAMETERS NOT SPECIFIED<strong>7171</strong> & <strong>7171</strong> TML This error message appears when there is an error loadingthe <strong>7171</strong>10 or <strong>7171</strong>MLNK sub utilities. <strong>The</strong> user did not specify one ormore required parameters. Return to the screen and input ALL requiredparameters.RESET CHAR MUST BE AN <strong>ASCII</strong> CTRL CHAR<strong>7171</strong> TERM This communications error message appears when the valuespecified is not a valid Reset character. All Reset characters must be <strong>ASCII</strong>control characters (OO-IF). Redefine the invalid Reset character.TOO MANY TERMTYPS, MAX = on *<strong>7171</strong>LINK This error message appears in the output listing when the<strong>7171</strong>LINK TERMTYPS table overflows: Relink using fewer terminals inthe input . CTL file.xxxxxxxx DUPLICATE TERMINAL NAME LINKED - non-fatal error, processingcontinues<strong>7171</strong>LINK This error message appears in the output listing when a terminaltable has the same terminal name as a previously linked table. <strong>The</strong> outputimage MAY be partially usable, but ·only the first terminal table will beaccessible (the duplicate(s) will not be accessible).c-76 <strong>IBM</strong> <strong>7171</strong> Reference Manual and Programming Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!