<strong>GENERATOR</strong> INFORMATIONUSE OF ELECTRIC MOTORSThe power required to start an electric motor is considerablymore than is required to keep it running after it is started.Some motors require much more current to start than others.Split-phase (AC) motors require more current to start, undersimilar circumstances, than other types. They are commonlyused on easy-starting loads, such as washing machines, orwhere loads are applied after the motor is started, such assmall power tools. Because they require 5 to 7 times as muchcurrent to start as to run, their use should be avoided, wheneverpossible, if the electric motor is to be driven by a smallgenerator. Capacitor and repulsion-induction motors requirefrom 2 to 4 times as much current to start as to run. The CUTrentrequired to start any motor varies with the load connectedto it. An electric motor connected to an aircompressor, for example, will require more current than amotor to which no load is connected.In general, the current required to start 115 volt motorsconnected to medium starting loads will be approximatelyas follows:AMPS FORAMPS FORMOTOR SIZE RUNNING STARTING(HP) (AMPERES) (AMPERES)1/6 3.2 6.4 TO 22.41/4 4.6 9.2 TO 32.21/3 5.2 10.4 TO 72.81/2 7.2 14.4 TO 29.23/4 10.2 20.4 TO 40.81 13 26 TO 52REQUIREO OPERATING SPEEDAlthough individual units may vary slightly, the normalvoltage and frequency of typical 60 (50) hertz engine-drivengenerators described in this manual are approximately as follows:run first with no load applied, then at half the generator'scapacity, and finally loaded to its full capacity as indicated onthe generator's data plate.The output voltage should be checked periodically to ensureproper operation of the generating plant and the appliances itsupplies.<strong>GENERATOR</strong> FREQUENCY ADJUSTMENT• Frequency is a direct result of engine/generator speed, asindicated by the following:• When the generator is run at 3600 rpm, the AC voltageoutput frequency is 60 hertz.• When the generator is run at 3000 rpm, the AC voltageoutput frequency is 50 hertz.Therefore, to change the generator's frequency, the generator'sdrive engine's speed must be changed. A reconfiguring of theAC output connections at the generator must also be made.<strong>GENERATOR</strong> MAINTENANCEMaintaining cleanliness is important. Do not allow salt, dust,or carbon from engine exhaust to build up on either the generatoror its engine.NOTE: In the above table the maximum "AMPS FORSTARTING" is more for some small motors than for largerones. The reason for this is that split-phase (the hardest startingtypes) are used in the smaller motors only.Because the heavy surge of current needed for startingmotors is required for only an instant, the generator will notbe damaged if it can bring the motor up to speed in a fewseconds. If difficulty is experienced in starting motors, tumoff all other electrical loads and, if possible, reduce the loadon the electric motor.BAND-FLANGEREARCAPACITORPFRONT COVER<strong>GENERATOR</strong> COMPONENTSCONTROL BOXEngines & Generators31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!