12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Light Hydrocarbon AnalysisSpecial Columns for Unsaturated Light Hydrocarbons• Faster separations of C1 to C4 hydrocarbons.• Res-Sil® packing replaces Porasil materials.n-Octane on Res-Sil® C Packed ColumnThis packed column has unique selectivity for resolving unsaturatedlight hydrocarbons (Figure 1).OPN on Res-Sil® C Packed ColumnThis column separates the light hydrocarbons, and baselineresolves cis-2-butene from 1,3-butadiene (Figure 2).2abc Refinery Gas Column SetThis 3-column set is finely tuned to resolve light hydrocarbons.When used in the proper valving system, it will elute C5+ hydrocarbonsahead of C1 through C4 hydrocarbons. (Figure 3)Description cat.#* pricen-Octane on Res-Sil C, 80/100 (20', 2.0mm ID,1/8" Silcosmooth OD) 80436-OPN on Res-Sil C, 80/100 (12', 2.0mm ID, 1 /8" Silcosmooth OD) 80437-2abc Refinery Gas Column Set (3 column set)** 88000-*Please add column instrument configuration suffix number to cat.# whenordering. See page 143.**This column set is for a valving system; therefore, packing material is filled toends of <strong>columns</strong>.Figure 1 n-Octane on Res-Sil® C packing has uniqueselectivity for unsaturated light hydrocarbons.142,3 5 78for more info6min. 0 2 4 691011121. methane2. ethane3. ethylene4. acetylene5. propane6. propylene7. isobutane8. n-butane9. 1-butene10. pentane11. isobutylene12. 1,3-butadiene13. 1-pentene14. trans-2-pentene15. cis-2-pentene16. 2-methylbutene-2n-octane 80/100 Res-Sil ® C20', 1 /8" OD x 2mm ID, SilcoSmooth ® tubing (cat. # 80436)Oven temp.: 60°CInj. temp.: 150°CDet. temp: 150°C FIDFlow rate: 30mL/min. HeSample: refinery gas C1-C5Sample size: 20µLSee page 135 for more information on Res-Sil® packing materials.1314158 10 12GC_PC0037216GC COLUMNS | PACKED/MICROPACKED COLUMNSSpecialty Packed ColumnsFigure 2 OPN on Res-Sil® C packing has uniqueselectivity for cis-2-butene and 1,3-butadiene.Retention1 2 4 536789101112Indices1. methane 1002. ethane/ethylene 2003. acetylene 2604. propane 3005. propylene 3216. propadiene 3457. isobutane 3868. butane 4009. 1-butene 42210. isobutylene/trans-2-butene 43411. cis-2-butene 44312. 1,3-butadiene 45413. isopentane 48814. pentane/3-methyl-1-butene 50315. 1-pentene 52216. trans-2-pentene 53317. cis-2-pentene 54018. 2-methyl-2-butene 5491314min. 0 5 10cis-2-butene/1,3-butadieneresolved to baseline15 16 17 18OPN on Res-Sil ® C, 80/100 mesh, 12' x 2mm ID x 1 /8" OD in SilcoSmooth ®tubing (cat.# 80437). 20µL on-column injection of refinery gas.Concentration: 0.1-6 absolute mole %Oven temp.: 50°CInj. & det. temp.: 200°CCarrier gas: heliumFlow rate: 30mL/minReference standard courtesy of AC Analytical Controls, Bensalem, PA.GC_PC00373Figure 3 Refinery gas calibration standard on a Restekrefinery gas packed column set.3,4 5216789101112131415161. C5=C6+2. methane3. ethane4. ethylene5. propane6. acetylene7. propylene8. cyclopropane9. isobutane10. propadiene11. n-butane12. 1-butene13. isobutene14. trans-2-butene15. cis-2-butene16. 1,3-butadiene17. isopentane18. n-pentanemin. 10 20 30 GC_PC003742abc Refinery Gas Column Set (cat.# 88000-875) (3 column set)Oven temp.: 60°CInj. temp.: 150°CDet. temp: 150°C FIDFlow rate: 30mL/min., heliumSample: refinery gasSample size: 1cc1718www.restek.com 129Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!