12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GC COLUMNS | HIGH-PERFORMANCE Rxi COLUMNSRxi® Columns OverviewColumn Cross-Reference TableRxi® <strong>columns</strong> produce the same selectivity as competitor <strong>columns</strong>, but are much more inert, exhibit lower bleed, and offerexceptional reproducibility. For more accurate, reliable trace-level results, choose Rxi® <strong>columns</strong>.–polar POLARITY non-polar+RestekRxi-1msRxi-1HT100% dimethylpolysiloxaneHP-1ms UI, DB-1ms UI,HP-1, HP-1ms, DB-1DB-1ms, Ultra-1Rxi-5ms 5% diphenyl/ HP-5ms UI,CP-Sil 895% dimethyl HP-5, HP-5ms,CP Sil 8 CBpolysiloxaneDB-5, Ultra-2Rxi-5Sil MSRxi-5HTRxi-XLBRxi-624Sil MSRxi-35Sil MSRxi-17Sil MSPhaseComposition100% dimethylpolysiloxane5% phenyl, 95% dimethylarylene polysiloxane5% diphenyl/95%dimethyl polysiloxanearylene/methylmodified polysiloxane6% cyanopropylphenyl,94% dimethyl arylenepolysiloxane35% phenyl, 65% dimethylarylene polysiloxane50% phenyl, 50% dimethylarylene polysiloxaneAgilentDB-1HTDB-5ms UI, DB-5msDB-5HTDB-XLBDB-624, HP-624DB-35msDB-17ms, HP-17,DB-17VF-1msCP-Sil 5CP Sil 5 CB Low Bleed/MSVF-5msCP-Sil 8 CB Low Bleed/MSVF-5HTVF-XmsVF-624msVF-35msVF-17msCP-Sil 24 CBBP-1BP-5BPX-5BP-624BPX-50ZB-1ZB-1msZB-5ZB-5msZB-5msZB-5HTMR1ZB-624Rxi-17 50% diphenyl/50% HP-17, DB-17,CP-Sil 24 CB ZB-50dimethyl polysiloxane DB-608, HP-50+Varian/Chrompack SGE Phenomenex Machery-Nagel SupelcoVF-1HTBP-35ZB-1HTMR2ZB-50Optima-1Optima-1msOptima-1ms AccentOptima-5Optima-5msOptima-5ms AccentOptima-XLBOptima-624Optima-35msOptima-17Optima-17msSPB-1Equity-1SPB-5Equity-5SLB-5msVisit www.restek.com/rxi for detailed comparisonsand to learn how exceptional Rxi® inertness, bleed,and reproducibility can improve your data.Use Rxi® Guard/RetentionGap Columns to protect youranalytical column and help focusanalytes.Rxi® Guard/Retention Gap Columns (fused silica)• Extend column lifetime.• Excellent inertness—obtain lower detection limits for active compounds.• Sharper chromatographic peaks by utilizing retention gap technology.• Maximum temperature: 360°C.Nominal ID Nominal OD 5-Meter 5-Meter/6-pk. 10-Meter 10-Meter/6-pk.0.25mm 0.37 ± 0.04mm 10029 10029-600 10059 10059-6000.32mm 0.45 ± 0.04mm 10039 10039-600 10064 10064-6000.53mm 0.69 ± 0.05mm 10054 10054-600 10073 10073-60040 www.restek.comWebsite : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!