GC COLUMNS | HIGH-PERFORMANCE Rxi COLUMNSRxi® Columns OverviewColumn Cross-Reference TableRxi® <strong>columns</strong> produce the same selectivity as competitor <strong>columns</strong>, but are much more inert, exhibit lower bleed, and offerexceptional reproducibility. For more accurate, reliable trace-level results, choose Rxi® <strong>columns</strong>.–polar POLARITY non-polar+RestekRxi-1msRxi-1HT100% dimethylpolysiloxaneHP-1ms UI, DB-1ms UI,HP-1, HP-1ms, DB-1DB-1ms, Ultra-1Rxi-5ms 5% diphenyl/ HP-5ms UI,CP-Sil 895% dimethyl HP-5, HP-5ms,CP Sil 8 CBpolysiloxaneDB-5, Ultra-2Rxi-5Sil MSRxi-5HTRxi-XLBRxi-624Sil MSRxi-35Sil MSRxi-17Sil MSPhaseComposition100% dimethylpolysiloxane5% phenyl, 95% dimethylarylene polysiloxane5% diphenyl/95%dimethyl polysiloxanearylene/methylmodified polysiloxane6% cyanopropylphenyl,94% dimethyl arylenepolysiloxane35% phenyl, 65% dimethylarylene polysiloxane50% phenyl, 50% dimethylarylene polysiloxaneAgilentDB-1HTDB-5ms UI, DB-5msDB-5HTDB-XLBDB-624, HP-624DB-35msDB-17ms, HP-17,DB-17VF-1msCP-Sil 5CP Sil 5 CB Low Bleed/MSVF-5msCP-Sil 8 CB Low Bleed/MSVF-5HTVF-XmsVF-624msVF-35msVF-17msCP-Sil 24 CBBP-1BP-5BPX-5BP-624BPX-50ZB-1ZB-1msZB-5ZB-5msZB-5msZB-5HTMR1ZB-624Rxi-17 50% diphenyl/50% HP-17, DB-17,CP-Sil 24 CB ZB-50dimethyl polysiloxane DB-608, HP-50+Varian/Chrompack SGE Phenomenex Machery-Nagel SupelcoVF-1HTBP-35ZB-1HTMR2ZB-50Optima-1Optima-1msOptima-1ms AccentOptima-5Optima-5msOptima-5ms AccentOptima-XLBOptima-624Optima-35msOptima-17Optima-17msSPB-1Equity-1SPB-5Equity-5SLB-5msVisit www.restek.com/rxi for detailed comparisonsand to learn how exceptional Rxi® inertness, bleed,and reproducibility can improve your data.Use Rxi® Guard/RetentionGap Columns to protect youranalytical column and help focusanalytes.Rxi® Guard/Retention Gap Columns (fused silica)• Extend column lifetime.• Excellent inertness—obtain lower detection limits for active compounds.• Sharper chromatographic peaks by utilizing retention gap technology.• Maximum temperature: 360°C.Nominal ID Nominal OD 5-Meter 5-Meter/6-pk. 10-Meter 10-Meter/6-pk.0.25mm 0.37 ± 0.04mm 10029 10029-600 10059 10059-6000.32mm 0.45 ± 0.04mm 10039 10039-600 10064 10064-6000.53mm 0.69 ± 0.05mm 10054 10054-600 10073 10073-60040 www.restek.comWebsite : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011
Rxi®-1ms Columns (fused silica)(nonpolar phase, Crossbond® 100% dimethyl polysiloxane)• General purpose <strong>columns</strong> for drugs of abuse, essential oils, hydrocarbons, pesticides,PCB congeners (e.g. Aroclor mixes), sulfur compounds, amines, solvent impurities,simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.• Tested and guaranteed for ultra-low bleed—improved signal-to-noise ratio, forbetter sensitivity and mass spectral integrity.• Temperature range: -60 °C to 330/350 °C (bleed tested temperature/maximumoperating temperature).• Equivalent to USP G2 phase.ID df temp. limits 15-Meter 30-Meter 60-Meter0.25mm 0.25µm -60 to 330/350°C 13320 13323 133260.50µm -60 to 330/350°C 13335 13338 133411.00µm -60 to 330/350°C 13350 13353 133560.32mm 0.25µm -60 to 330/350°C 13321 13324 133270.50µm -60 to 330/350°C 13336 13339 133421.00µm -60 to 330/350°C 13351 13354 133574.00µm -60 to 330/350°C 133960.53mm 0.50µm -60 to 330/350°C 13337 133401.00µm -60 to 330/350°C 13352 133551.50µm -60 to 330/350°C 13367 13370 13373ID df temp. limits 10-Meter 12-Meter 20-Meter 25-Meter 50-Meter0.10mm 0.10µm -60 to 330/350°C 133010.18mm 0.18µm -60 to 330/350°C 133020.36µm -60 to 330/350°C 133110.20mm 0.33µm -60 to 330/350°C 13397 13398 13399GC COLUMNS | HIGH-PERFORMANCE Rxi COLUMNSRxi®-1ms, Rxi®-5msRxi®-1ms StructureCH 3SiCH 3100%similar phasesDB-1, DB-1ms, HP-1, HP-1ms, Ultra-1, SPB-1,Equity-1, VF-1ms, CP-Sil 5 CB Low Bleed/MSOfreeliteratureRxi®-1ms: TheUltimate HighPerformance FusedSilica CapillaryColumnDownload your freecopy fromwww.restek.comlit. cat.# 580075BRxi®-5ms Columns (fused silica)(low polarity phase, Crossbond® 5% diphenyl/95% dimethyl polysiloxane)• General purpose <strong>columns</strong> for semivolatiles, phenols, amines, residual solvents, drugsof abuse, pesticides, PCB congeners (e.g. Aroclor mixes), solvent impurities.• Most inert column on the market.• Tested and guaranteed for ultra-low bleed—improved signal-to-noise ratio, forbetter sensitivity and mass spectral integrity.• Temperature range: -60 °C to 330/350 °C (bleed tested temperature/maximumoperating temperature).• Equivalent to USP G27 phase.ID df temp. limits 15-Meter 30-Meter 60-Meter0.25mm 0.25µm -60 to 330/350°C 13420 13423 134260.40µm -60 to 330/350°C 134810.50µm -60 to 330/350°C 13435 13438 134411.00µm -60 to 330/350°C 13450 13453 134560.32mm 0.25µm -60 to 330/350°C 13421 13424 134270.50µm -60 to 330/350°C 13436 13439 134421.00µm -60 to 330/350°C 13451 13454 134570.53mm 0.25µm -60 to 330/350°C 13422 134250.50µm -60 to 330/350°C 13437 134401.00µm -60 to 330/350°C 13452 134551.50µm -60 to 330/350°C 13467 13470ID df temp. limits 10-Meter 12-Meter 20-Meter 25-Meter 50-Meter0.10mm 0.10µm -60 to 330/350°C 134010.18mm 0.18µm -60 to 330/350°C 134020.30µm -60 to 330/350°C 134090.36µm -60 to 330/350°C 134110.20mm 0.33µm -60 to 330/350°C 13497 13498 13499SiRxi®-5ms Structure5%Osimilar phasesCH 3SiCH 395%DB-5, HP-5, HP-5ms, Ultra-2, SPB-5, Equity-5,CP-Sil 8OfreeliteratureRxi®-5ms ColumnsDownload your freecopy fromwww.restek.comlit. cat.# 580046Awww.restek.com 41Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011