12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Simulated Distillation (C5-C44) AnalysisRtx®-2887 Column (fused silica)(nonpolar phase; Crossbond® 100% dimethyl polysiloxane—for simulated distillation)• Application-specific column for simulated distillation.• Stable to 360 °C.GC COLUMNS | APPLICATION-SPECIFIC COLUMNSPetroleum & Petrochemicalalso availableRtx®-1 SimDist 2887—a packed column forprocess instrumentation. See page 126.The Rtx®-2887 column’s stationary phase, column dimensions, and film thickness havebeen optimized to exceed the resolution and skewing factor requirements currentlyspecified in ASTM method D2887. Each column is individually tested to guarantee astable baseline with low bleed and reproducible retention times. The Crossbond®methyl silicone stationary phase has increased stability compared to packed <strong>columns</strong>,ensuring stable baselines and shorter conditioning times.ID df temp. limits 10-Meter0.53mm 2.65µm -60 to 360°C 10199MXT®-2887 Column (Siltek® treated stainless steel)(nonpolar phase; Crossbond® 100% dimethyl polysiloxane—for simulated distillation)• Application-specific <strong>columns</strong> for simulated distillation.• Stable to 400 °C.ID df temp. limits 10-Meter0.53mm 2.65µm -60 to 400°C 70199MXT®-1HT SimDist Column (Siltek® treated stainless steel)(nonpolar phases)• Stable up to 400 °C—lowest bleed for longest column lifetime.• Reliably meets all ASTM D2887 specifications.• 100% dimethyl polysiloxane phase allows easy comparisons to historical data.ID df temp. limits 10-Meter0.53mm 2.65µm -60 to 360/400°C 70132NEW!similar phasesDB-2887, Petrocol EX2887similar phasesDB-2887, Petrocol EX2887, CP-HT-Simdist CBsimilar phasesDB-1HT, CP-HT-Simdist CBSee page 78 for more dimensions.Simulated distillation on an Rtx®-2887 column.Column: Rtx ® -2887, 10m, 0.53mm ID, 2.65µm (cat.# 10199)Sample: 1µL direct injection of 0.01-0.1 wt. % C5 to C44 hydrocarbon standardin carbon disulfideInj. temp.: 360°CDet. temp: 360°CCarrier gas: helium (constant flow)Linear velocity: 15mL/min. (112cm/sec.)Oven temp.: 35°C to 360°C @ 15°C/min. (hold 5 min.)1. C52. C63. C74. C85. C96. C107. C118. C129. C1410. C1611. C1812. C2013. C2414. C2815. C3216. C3617. C4018. C44GC_PC00750www.restek.com 77Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!