12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GC COLUMNS | APPLICATION-SPECIFIC COLUMNSPetroleum & Petrochemicalsimilar phasesDB-1HT, CP-HT-Simdist CBASTMMethodD2887D7213 C5 - C60(D2887-ext)D3710D5307D6352D7500D7169HydrocarbonRangeC5 - C44gasolineup to C14crudeup to C42C10 - C90C7 - C110C5 - C100cat. #70131701327013170115701127013270115701127011570112701157011270115NEW!Method Recommended ColumnsConfiguration5m x 0.53mm, 0.88µm10m x 0.53mm, 2.65µm5m x 0.53mm, 0.88µm5m x 0.53mm, 0.20µm5m x 0.53mm, 0.10µm10m x 0.53mm, 2.65µm5m x 0.53mm, 0.20µm5m x 0.53mm, 0.10µm5m x 0.53mm, 0.20µm5m x 0.53mm, 0.10µm5m x 0.53mm, 0.20µm5m x 0.53mm, 0.10µm5m x 0.53mm, 0.20µmSimulated Distillation (C44-C100) AnalysisMXT®-1HT SimDist Column (Siltek® treated stainless steel)(nonpolar phases)• Stable up to 450 °C—lowest bleed for longest column lifetime.• Reliably meet all ASTM D6352, D7169, and D7500 specifications.• 100% dimethyl polysiloxane phase allows easy comparisons to historical data.Accurate boiling point determination for medium and heavy fractions using GCsimulated distillation requires <strong>columns</strong> and phase polymers that are robust enoughto withstand high temperatures without significant degradation. Metal <strong>columns</strong> area better alternative than fused silica, and the MXT®-1HT SimDist <strong>columns</strong> are thelowest bleed, highest efficiency <strong>columns</strong> available, outperforming other metal<strong>columns</strong> for critical method parameters.ID df temp. limits 5-Meter 10-Meter0.53mm 0.10µm -60 to 430/450°C 701120.20µm -60 to 430/450°C 701150.21µm -60 to 430/450°C 701180.88µm -60 to 400/430°C 70131 701341.00µm -60 to 380/400°C 701301.20µm -60 to 380/400°C 701192.65µm -60 to 360/400°C 701325.00µm -60 to 360/400°C 70133Low bleed, high efficiency MXT®-1HT SimDist <strong>columns</strong> outperform competitors (ASTM D6352 conditions).Restek, 5m x 0.53mm x 0.2μmC50/C52R = 2.89Lower bleed means:• Longer column lifetime.• More stable calibrations.• Accurate boiling point determinations.RESTEK ADVANTAGE:Longer column lifetime andmore accurate data!Bleed = 14pA0 10 20 30 40Time (min)GC_PC1149Agilent/ J&W, 5m x 0.53mm x 0.15μmC50/C52R = 1.81Bleed = 61pAHigher efficiency means:• Greater resolution; analyze more samplesbefore method criteria are reached.• Assured method performance.RESTEK ADVANTAGE:Run more samples within methodspecifications!0 10 20 30 40Time (min)GC_PC1150Varian, 5m x 0.53mm x 0.17μmC50/C52R = 1.84Bleed = 57pA0 10 20 30 40Time (min)GC_PC115178 www.restek.comWebsite : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!