12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GC COLUMNS | HIGH-PERFORMANCE RXI COLUMNSRxi® Columns OverviewFigure 3 An Rxi®-5ms column givesthe highest response for both basicand acidic compounds.Response Factor (RF)Response Factor (RF)1.0000.8000.6000.4000.2000.0000.3000.2500.2000.1500.1000.0500.0002 ng of pyridineRxi-5msRxi-5msZB-5ZB-5 MSVF-5msHP-5msDB-5msDB-5Column2 ng of 2,4-dinitrophenolZB-5ZB-5 MSVF-5msHP-5msDB-5msDB-5ColumnComparison of 30m x 0.25mm ID, 0.25μm<strong>columns</strong>.Innovation & Service“When my research group needed aGC column for a chiral separation,Restek was the only company thatoffered to provide us with test<strong>columns</strong> to evaluate. The willingnessof Restek to work with us to find asolution to our separation problem isexceptional.”Joe Dinnocenzo,Professor of ChemistryDirector, Center forPhotoinduced Charge TransferUniversity of RochesterFigure 2 Analyte levels in samples are unknown; only inert <strong>columns</strong>, which preventconcentration from affecting retention time, can assure accurate results.A: Pyridine on non-Rxi® columnB: Pyridine on-Rxi® columnRetention times vary withconcentration; poor peakshape requires manualintegration and additionalreview.2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 Time.GC_EX0111810 ng, 2.26 min.2.5 ng, 2.28 min.1.0 ng, 2.32 min.extracted ion chromatogram, m/z 792.25 2.30 2.35 2.40 2.45 2.50 2.55 2.60 Time.GC_EX01119Predictable retentiontimes, regardless ofconcentration; easy,accurate integration.10 ng, 2.39 min.1 ng, 2.40 min.0.5 ng, 2.41 min.Improved Response for Difficult CompoundsAnother reason column inertness is important for trace-level analysis is that many acidic,basic, and polar compounds will tail significantly and become difficult to analyze if the columncontains active sites. The remarkable neutrality of Rxi® <strong>columns</strong> solves this problemand allows a wide range of compounds to be analyzed with high sensitivity, often on a singlecolumn. All Rxi® <strong>columns</strong> are exceptionally inert as demonstrated in Figure 3 by highresponse factors for both pyridine (basic) and 2,4-dinitrophenol (acidic). Rxi® <strong>columns</strong> reliablyproduce highly symmetric peaks and improved responses for difficult compounds,indicating greater inertness than <strong>columns</strong> produced by other manufacturers (Figure 4).Figure 4 Rxi® <strong>columns</strong> are the most inert <strong>columns</strong> on the market providingthe most symmetric peak shape for basic compounds, such as pyridine.DB-5ZB-5ZB-5msRxi ® -5msDB-5msSymmetric peaks give high responseand predictable retention times.VF-5msHP-5msHow can we help you today?Contact support@restek.com or yourlocal Restek representative for helpful,knowledgeable technical support.Comparison of 30m x 0.25mm ID, 0.25µm 5% diphenyl <strong>columns</strong>, 2ng pyridine on-column, helium carrier gas,Oven temp.: 50°C (3 min.) to 180°C @ 35°C/min. (5 min.), Det.: FID @ 250°C38 www.restek.comWebsite : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!