12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GC COLUMNS | APPLICATION-SPECIFIC COLUMNSPetroleum & PetrochemicalAromatics & Oxygenates in Gasoline AnalysisRt®-TCEP Columns (fused silica)(highly polar phase; 1,2,3-tris[2-cyanoethoxy]propane—not bonded)• General purpose <strong>columns</strong>, ideal for aromatics and oxygenates in gasoline.• Temperature range: 0 °C to 135 °C.Most gasolines contain aliphatic hydrocarbons up to n-dodecane (C12). To improveidentification of the aromatics and oxygenates, it is desirable to elute benzene after C11and toluene after C12. The extremely polar Rt®-TCEP stationary phase provides aretention index for benzene greater than 1100 and permits the separation of alcoholsand aromatics from the aliphatic constituents in gasoline.Rt®-TCEP <strong>columns</strong> have the same high polarity as TCEP packed <strong>columns</strong> (pre<strong>columns</strong>in ASTM Method D4815 for the analysis of petroleum oxygenates), with the efficiencyof a capillary column. The result is a column that can separate a wide variety of compoundswith an elution pattern unattainable using other high polarity siloxanes.similar phasesSPB-TCEP, CP-TCEPThe Rt®-TCEP column incorporates a nonbonded stationary phase coated on a surfacespecialized for enhanced polymer stability and extended column lifetime. Solvent rinsingshould be avoided. Conditioning is necessary only if the column is to be used attemperatures near the maximum operating temperature.ID df temp. limits 30-Meter 60-Meter0.25mm 0.40µm 0 to 135°C 10998 10999Petroleum oxygenates on an Rt®-TCEP column.121. methyl tert-butyl ether2. n-undecane3. tert-butanol4. methanol5. isopropyl alcohol6. ethanol7. n-dodecane8. n-tridecane9. n-butanol35 6 7894min. 2 4 6 8 10 12 14 16GC_PC00195Column: Rt ® -TCEP, 60m, 0.25mm ID, 0.4µm (cat.# 10999)Inj.:1.0µL split injection, components @ 500ppm.Oven temp.: 60°C (hold 5 min.) to 100°C @ 5°C/min. (hold 10 min.)Inj./det. temp.: 200°CCarrier gas: heliumLinear velocity: 30cm/sec. set @ 80°CFID sensitivity: 6.4 x 10 -11 AFSSplit flow: 46mL/min.Solutions For Your Petroleum & Petrochemical AnalysesImproved best-in-class GC <strong>columns</strong> • Standards • Industry experts at your service.Visit us at www.restek.com/petro80 www.restek.comWebsite : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!