12.07.2015 Views

gc columns

gc columns

gc columns

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GCxGC Second Dimension Selectivity KitThe selectivity kit contains four <strong>columns</strong> of different selectivity for method development.Includes one each of the following:• Rxi®-17, 50% diphenyl dimethylpolysiloxane• Rtx®-CLPesticides, trifluoropropyl containing polymer• Stabilwax®, polar polyethylene glycol• Rt®-LC350, liquid crystalline phase selective for aromatic compoundsGC COLUMNS | GCXGCComprehensive GCDescription qty. cat.# priceGCxGC Second Dimension Selectivity Kit kit 15105Columns can also be purchased individually.Rxi-17, 1.1m (±3cm), 0.10mm ID, 0.10µm ea. 15104Rtx-CLPesticides, 1.1m (±3cm), 0.10mm ID, 0.10µm ea. 15103Stabilwax, 1.1m (±3cm), 0.10mm ID, 0.10µm ea. 15102Rt-LC350, 1.1m (±3cm), 0.15mm ID, 0.10µm ea. 15101Fragrance Allergens on Rxi®-1ms & Rxi®-17 (GC x GC)GC_FF010101. limonene2. 1-fluoronaphthalene3. benzyl alcohol4. phenyl acetaldehyde5. eucalyptol6. linalool7. camphor8. methyl-2-octynoate9. estragole10. citronellol11. citral 112. trans-cinnamaldehyde13. geraniol14. citral 215. anise alcohol16. hydroxycitronellol17. safrole18. cinnamyl alcohol19. methyl-2-nonynoate20. eugenol21. methyl eugenol22. coumarin23. hydroxycitronellolcontaminant24. isoeugenol25. α-isomethyl ionone 126. lilial27. α-isomethyl ionone 228. amyl cinnamal29. lyral 130. lyral 231. amylcinnamyl alcohol 132. amylcinnamyl alcohol 233. farnesol 134. farnesol 235. hexyl cinnamal 136. benzyl benzoate37. hexyl cinnamal 238. benzyl salicylate39. benzyl cinnamateColumns: Rxi ® -1ms, 30m, 0.25mm ID, 0.25µm (cat.# 13323)Rxi ® -17, 1m, 0.10mm ID, 0.10µm (10m, cat.# 13501)Sample: fragrance allergens in MTBEInstrument: LECO Corporation GCxGC/FID with quad-jet, dual-stagemodulator and secondary ovenInj.: 0.2µL split (split ratio 1:200),4mm laminar cup splitter (cat.# 20801)Inj. temp.: 250°CCarrier gas: helium, corrected constant flow via pressure rampsFlow rate:Oven temp.:2mL/min.Rxi ® -1ms: 40°C (hold 1 min.) to 240°C @ 4°C/min.Rxi ® -17: 45°C (hold 1 min.) to 245°C @ 4°C/min.Modulation: modulator temperature offset: 20°Csecond dimension separation time: 3 sec.hot pulse time: 0.8 sec.cool time between stages: 0.7 sec.Det.: FID @ 300°Cmakeup flow + column flow: 50mL/min.hydrogen: 40mL/min.air: 450mL/min.data collection rate: 200 HzGC_FF01011www.restek.com 61Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!