XTreme EFIS - STRATOMASTER Instrumentation MGL Avionics
XTreme EFIS - STRATOMASTER Instrumentation MGL Avionics
XTreme EFIS - STRATOMASTER Instrumentation MGL Avionics
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>XTreme</strong>-<strong>EFIS</strong> Operating Manual Page 153.4.4.5 Single fuel flow only indicatorThis mode is displayed if either fuel flow 1 or fuel flow 2 is selected and no fuel level senders are selected.3.4.4.6 Dual fuel flow indicatorThis mode is displayed if both fuel flow 1and fuel flow 2 are selected and the fuel mode is selected for dual flow. Both fuellevel senders are disabled.3.4.4.7 Single tank level indicatorThis mode is displayed if either fuel level 1 or fuel level 2 is selected. Both fuel flow senders are disabled.3.4.4.8 Dual tank level indicatorThis mode is displayed if both fuel level 1 and fuel level 2 are selected. Both fuel flow senders are disabled.3.4.4.9 Differential/Summed fuel flowThis mode is displayed if both fuel flow 1 and fuel flow 2 are selected and the fuel mode is selected for either differentialor summed.3.4.5 EGT/CHT display sectionThe <strong>XTreme</strong> supports up to 12 thermocouples for EGTs/CHTs. The EGT/CHT section willautomatically try and maximize the display area according to the number of EGTs/CHTsselected. The EGT/CHT parameters can be configured in the “EGT SETUP” and “CHT SETUP”menu.