<strong>XTreme</strong>-<strong>EFIS</strong> Operating Manual Page 644.5.4 Volts Setup<strong>EFIS</strong> VOLTS DISPLAY:This enables or disables the volts display on the <strong>EFIS</strong> and MFD displays.VOLTS DISPLAY MAX:Select the maximum value that you want the volts bargraph in the EMS display to show. This can give you increaseddisplay resolution.VOLTS DISPLAY MIN:Select the minimum value that you want the volts bargraph in the EMS display to show. This can give you increaseddisplay resolution.HIGH ALARM:This enables or disables the volts high alarm.HIGH ALARM:Enter the voltage threshold for when the high alarm must be activated. Any voltage above this value will activate thealarm.HIGH CAUTION:Enter the voltage for the high caution. This is the lower value of the upper yellow band.LOW CAUTION:Enter the voltage for the low caution. This is the upper value of the lower yellow band.LOW ALARM:This enables or disables the volts low alarm.LOW ALARM:Enter the voltage threshold for when the low alarm must be activated. Any voltage below this value will activate the alarm.VOLTS CALIBRATION FACTOR:During the factory calibration a factor has been determined and entered here that will give you an accurate volts reading.If you would like to adjust this value then measure the supply voltage with a multimeter and adjust the calibration factoruntil the Xtreme matches that of the multimeter.