Section 6Electrical SystemProblem: Water Will Not Run Into The Sump TroughDuring The Freeze CycleStep 1 Verify water is supplied to the ice machine, andthen start a new freeze sequence by moving the <strong>ICE</strong>/OFF/CLEAN toggle switch to OFF then back to <strong>ICE</strong>.Step 2 Wait until the freeze cycle starts (approximately45 seconds, the freeze cycle starts when thecompressor energizes), and then refer to chart.ImportantThis restart must be done prior to performingdiagnostic procedures. This assures the ice machineis not in a freeze cycle water inlet valve safety shutoffmode. You must complete the entire diagnosticprocedure within 6 minutes of starting.Is water flowing intothe water trough?The Water LevelLight is:Step 2 Checking for normal operationThe Water Inlet ValveSolenoid Coil is:Causeyes off Energized This is Normal Operation don’t change any partsno on or off Energized Or De-Energized Proceed to step 3Step 3 Leave the ice machine run, then disconnect thewater level probe from control board terminal 1F.ImportantFor the test to work properly you must wait until thefreeze cycle starts, prior to disconnecting the waterlevel probe. If you restart the test you mustreconnect the water level probe, restart the icemachine, (step 1) and then disconnect the waterlevel probe after the compressor starts.YELLOWCLEAN LIGHTDISCONNECTWATER LEVELPROBE FROMTERMINAL 1FGREENGREENREDWATER LEVEL LIGHTBIN SWITCH LIGHTHARVEST/SAFETY LIMITLIGHT1C1FSV1621GSV1588Figure 6-28. Step 3Is water flowing intothe water trough?Step 3 Disconnect water level probe from control board terminal 1FThe Water LevelLight is:The Water Inlet ValveSolenoid Coil is:Causeyes off Energized The water level probe is causing the problem.Clean or replace the water level probe.no off Energized The water inlet valve is causing the problem.no on or off De-Energized The control board is causing the problem.Part No. 80-1100-3 6-53

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!