ICE MACHINES Q-Model Service Manual

ICE MACHINES Q-Model Service Manual

ICE MACHINES Q-Model Service Manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Electrical System Section 6Q800/Q1000 -REMOTE - 3 PHASE WITHOUT TERMINAL BOARDSEE SERIAL PLATE FOR VOLTAGEL3 L2 L1(89)(55)CAUTION: DISCONNECT POWER BEFORE WORKINGON ELECTRICAL CIRCUITRY.DIAGRAM SHOWN DURING FREEZE CYCLE(60)(20)(61)(21)(22)WATERVALVEHPRSOLENOID (79)(78)(88)HIGH PRESCUTOUT243(77)HARVESTSOLENOID(80)(42)15(76)DUMPSOLENOID(81)(75)TRANS.FUSE (7A)(57)(98)WATERPUMP(99)<strong>ICE</strong> THICKNESS PROBEWATER LEVEL PROBENOT USEDBIN SWITCH(64)(62)(63)(65)1C1F1GLOW D.C.VOLTAGEPLUGTOGGLE SWITCH(68) <strong>ICE</strong>(67)(69)OFF(66)CLEAN(62)(58)(56)CLEAN LIGHTWATER LEVEL LIGHTBIN SWITCH LIGHT(59)HARVEST LIGHT/SAFETY LIMIT CODE LIGHTINTERNAL WORKINGVIEW(83)(82)LIQUID LINESOLENOIDCONTACTORCOIL(74)VIEW FOR WIRING6866676269L3L2L1CONTACTORCONTACTS(51)(85)(F2)(F1)T2REMOTEFAN MOTORT3T1COMPRESSORRUN CAPACITORREMOTE CONDENSERSV20746-32 Part No. 80-1100-3