Electrical System Section 6Q450/Q600/Q800/Q1000 - REMOTE - 1 PHASE WITHOUT TERMINAL BOARDCAUTION: DISCONNECT POWER BEFORE WORKINGON ELECTRICAL CIRCUITRY.SEE SERIAL PLATE FOR VOLTAGEL1DIAGRAM SHOWN DURING FREEZE CYCLE(20) (21)(22)L2 (N)(89)(55) (61)HPRSOLENOIDWATERVALVE(78) (79)HIGH PRESCUTOUT2(88)(42)4135TRANS.FUSE (7A)(60)(57)(88) (80)HARVESTSOLENOID(77)DUMPSOLENOID(98)(81)(99)WATERPUMP(75)(59) (83) (82)<strong>ICE</strong> THICKNESS PROBEWATER LEVEL PROBEAUCS DISPENSE TIME1C1F1GLOW D.C.VOLTAGEPLUGCLEAN LIGHTWATER LEVEL LIGHT(58)(56)CONTACTORCOIL(74)LIQUID LINESOLENOID(62)BIN SWITCH LIGHTBIN SWITCH(63)HARVEST LIGHT/SAFETY LIMIT CODE LIGHT(64)(65)TOGGLE SWITCH(67)(66)(68) <strong>ICE</strong>(69)OFF(62)CLEANVIEW FOR WIRING6662686769COMPRESSORRS(49)(47)RUN CAPACITOR(94)CONTACTORCONTACTS*OVERLOADC(46)RR(50)(48)(45)L1PTCR(51)F1F2REMOTEFAN MOTORREMOTE CONDENSERRUN CAPACITOR**SV20736-30 Part No. 80-1100-3