12.07.2015 Views

EAGLE CORR PE™ * - JM Eagle

EAGLE CORR PE™ * - JM Eagle

EAGLE CORR PE™ * - JM Eagle

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The physical (or chemical) properties of <strong>Eagle</strong> Corr PE Storm Drain pipe presented in this booklet represent typicalaverage values obtained in accordance with acceptedtest methods and are subject to normal manufacturingvariations. They are supplied as a technical service and aresubject to change without notice. Check with <strong>JM</strong> <strong>Eagle</strong> Product Assurance to ensure current information.How This Guide Can Help YouThis booklet was written especially for the installer and those who directthe actual handling and installation of <strong>Eagle</strong> Corr PE storm drain pipe. Thisguide should be used in conjunction with the following applicable industryaccepted installation and testing practices. This document should not beconsidered a full guide or manual in lieu of the following industry practices:1. AASHTO LRFD Bridge Construction Specification Section 30 –05 (or later)2. ASTM F449-02 (or later) “Practice for Subsurface Installation of CorrugatedPolyethylene Pipe for Agricultural Drainage or Water Table Control.”3. ASTM F1417-05 (or later) “Installation Acceptance of Plastic GravitySewer Lines Using Low-Pressure Air.”4. ASTM F1668-96 (2002) (or later) “Construction of Buried Plastic Pipe.”5. ASTM D2321-05 (or later) “Underground Installation of ThermoplasticPipe for Sewers and Other Gravity-Flow Applications.”6. ASTM F2487–“Standard Practice for Infiltration and Exfiltration AcceptanceTesting of Installed Corrugated High Density Polyethylene Pipelines.”This guide is meant as an explanatory supplement to the materials above onhow to install <strong>Eagle</strong> Corr PE storm drain pipe under normal conditions so asto comply with <strong>JM</strong> <strong>Eagle</strong> Installation Guide. Any discrepancies between theabove standards and the written information contained herein should be broughtto the attention of <strong>JM</strong> <strong>Eagle</strong> Product Assurance immediately for resolution by<strong>JM</strong> <strong>Eagle</strong> prior to any actions by either contractor, engineer, or municipality.This guide is not intended to supply design information nor to assume the responsibilityof the engineer (or other customer representative) in establishingprocedures best suited to individual job conditions so as to attain satisfactoryperformance.4 <strong>EAGLE</strong> <strong>CORR</strong> PE INSTALLATION GUIDE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!