12.07.2015 Views

DeviceNet Modules, Series 90-30, Manual, GFK-2196

DeviceNet Modules, Series 90-30, Manual, GFK-2196

DeviceNet Modules, Series 90-30, Manual, GFK-2196

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2<strong>DeviceNet</strong> Cable for the <strong>Series</strong> <strong>90</strong>-<strong>30</strong> <strong>Modules</strong><strong>Series</strong> <strong>90</strong>-<strong>30</strong> <strong>DeviceNet</strong> modules can be used with the either <strong>DeviceNet</strong> thick cable or thin cable.Thick cable permits greater cable lengths and higher current levels. Generally, thick cable is usedfor the trunk cable. Thin cable is normally used for shorter distances and is suitable for drop cablesand for installations where more cable flexibility is needed.Both thick cable and thin cable are 5-wire, multi-conductor copper cable. Two wires form atransmission line for network communications. A second pair transmits network power. The fifthconductor forms an electromagnetic shield. Most cables have color coded leads which correspondto the color coding on the terminals on the <strong>Series</strong><strong>90</strong>-<strong>30</strong> <strong>DeviceNet</strong> modules.Cable and Network SpecificationsThick Cable General SpecificationsThin Cable General SpecificationsTwo shielded pairs - Common axis with drain wire in centerOverall braid shield - 65% coverage; 36 AWG or 0.12mm tinned Cubraid minimum (individually tinned)Drain wire- #18 Copper min.; 19 strands minimum (individually tinned)Outside diameter - 0.410 inches (min) to 0.4<strong>90</strong> inches (max.) roundness- radius delta to be within 15% of 0.5 O.D.Two shielded pairs - Common axis with drain wire in centerOverall braid shield - 65% coverage; 36 AWG or 0.12mm tinned Cubraid minimum (individually tinned)Drain wire - #22 Copper; 19 strands minimum (individually tinned)Outside diameter - 0.240 inches (min.) to 0.280 inches (max.)roundness - radius delta to be within 20% of 0.5 O.D.Network TopologyBus with limited branching (trunkline/dropline)RedundancyNot SupportedNetwork Power for Node devices Nominal 24 VDC ±4%Allowed Nodes (Bridging excluded)Data Packet SizeDuplicate Address DetectionError Detection / Correction64 nodes0-8 bytes with allowance for message fragmentationAddresses verified at power-upCRC - retransmission of message if validity not acknowledged byrecipientBus Connector Pin AssignmentsThe <strong>DeviceNet</strong> connector on a <strong>Series</strong> <strong>90</strong>-<strong>30</strong> <strong>DeviceNet</strong> module has five color-coded screw-clampterminals. The connector provides bus continuity; it can be removed from the module withoutdisrupting bus operation.V+CAN_HSHIELDCAN_LV-Signal Pin Wire ColorV+ 5 RedCAN_H 4 WhiteShield 3 BareCAN_L 2 BlueV- 1 Black<strong>GFK</strong>-<strong>2196</strong> Chapter 2 Installation 2-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!