EN-32<strong>5000</strong> <strong>Series</strong> <strong>Indicators</strong>3.9 Print1 and Print2 MenusEnter this menu to define printing parameters. Default settings are bold.NOTE: The Print2 menu is only displayed if a second interface(RS232 or RS422/RS485) is installed.3.9.1 ResetSet the Print menu to factory defaults.NO = not reset.YES = reset.NOTE: If the Legal for Trade menu item is set to ON, the followingsettings are not reset: StableResetStable OnlyAuto PrintPrint ContentLayoutListEnd Print1(End Print2)No, YesOff, OnOff,On Stable (-> Load, Load and Zero),Interval (-> 0…3600), Continuous,On AcceptResult (-> Off, On, Numeric only),Gross (-> Off, On),Net (-> Off, On),Tare (-> Off, On),Header ( ->Off, On),User ID (-> Off, On),Project ID (-> Off, On),<strong>Scale</strong> ID (-> Off, On),Difference (-> Off, On),Date and Time (-> Off, On),Information (-> Off, On),Application Mode ( Off, On),Name (-> Off, On),Format (-> Multiple, Single),Feed (-> Line feed, 4 Line feed, Formfeed)No, YesExit PRINT1 menuExit PRINT2 menu3.9.2 Print Stable Data OnlySet the print criteria.OFF = values are printed immediately.ON = values are only printed when the stability criteria are met.3.9.3 Auto PrintSet the automatic printing functionality.OFF = disabled.ON.StAb = printing occurs each time the stability criteria are met.INtEr = printing occurs at the defined interval.CONt = printing occurs continuously.ACCEPt = printing occurs each time the display is within the Checkweigh accept range andstability criteria are met.
<strong>5000</strong> <strong>Series</strong> <strong>Indicators</strong>EN-33When ON.StAb is selected, set the condition for printing, where:LOAd = prints when the load is stable and greater than zeroLOAd.Zr = prints when any load is stable and equal to or greater than zero.When INtEr is selected, set the Print Interval.1 to 3600 (seconds)3.9.4 Print Content Sub-menuThis sub-menu is used to define the content of the printed data.ResultSet the status.OFF = DisabledON = the displayed reading is printed.NUM = only the numeric portion of the displayed reading is printed.GrossSet the status.OFFON= Disabled.= the Gross weight is printed.NetSet the status.OFFON= Disabled.= the Net weight is printed.TareSet the status.OFFON= Disabled.= the Tare weight is printed.HeaderSet the status.OFFON= Disabled.= the Header is printed.User IDSet the status.OFFON= Disabled.= the User ID is printed.