<strong>5000</strong> <strong>Series</strong> <strong>Indicators</strong>EN-33When ON.StAb is selected, set the condition for printing, where:LOAd = prints when the load is stable and greater than zeroLOAd.Zr = prints when any load is stable and equal to or greater than zero.When INtEr is selected, set the Print Interval.1 to 3600 (seconds)3.9.4 Print Content Sub-menuThis sub-menu is used to define the content of the printed data.ResultSet the status.OFF = DisabledON = the displayed reading is printed.NUM = only the numeric portion of the displayed reading is printed.GrossSet the status.OFFON= Disabled.= the Gross weight is printed.NetSet the status.OFFON= Disabled.= the Net weight is printed.TareSet the status.OFFON= Disabled.= the Tare weight is printed.HeaderSet the status.OFFON= Disabled.= the Header is printed.User IDSet the status.OFFON= Disabled.= the User ID is printed.