- Page 1: 026-1610 Rev 10 06-APR-2010 E2 Inst
- Page 6 and 7: 3.2.1 Single/Double Enclosures ....
- Page 8 and 9: 8.1 OVERVIEW ......................
- Page 10 and 11: 11.1.2.3 Floating Setpoint Control.
- Page 12 and 13: 11.7.13 Losing Contact With Zone Ap
- Page 14 and 15: 12 OPERATOR’S GUIDE TO USING THE
- Page 16 and 17: extensive sensor control, logging,
- Page 18 and 19: tion and system control, but they c
- Page 20 and 21: flipped from OFF to ON and from ON
- Page 22 and 23: 2.1.1 E2 Main Processor Board (CPU)
- Page 24 and 25: The Gateway board is an RS485 to RS
- Page 26 and 27: 810-3066 MultiFlex 168 810-3067 Mul
- Page 28 and 29: The PAK can control up to 4 condens
- Page 30 and 31: 2.2.6 4AO Analog Output Board The 4
- Page 32 and 33: floor managers of alarms and notice
- Page 35 and 36: 3 Mounting This section gives mount
- Page 37 and 38: 3.1.4 Blank Face Blank face control
- Page 39 and 40: 3.3.2 CC-100 Case Controller and CS
- Page 41 and 42: Figure 3-19 - External Repeater Mou
- Page 43 and 44: outside and inside temperature to m
- Page 45: 3.5.9 Dewpoint Probe 3.5.9.1 Locati
- Page 48 and 49: 4.1.3 Main Processor Board (Previou
- Page 50 and 51: Modem P/N Description 637-4871 COM3
- Page 52 and 53:
and replace it with an identical 3.
- Page 55 and 56:
5 Serial Configuration 5.1 Overview
- Page 57 and 58:
6 The RS485 Network and Hardware Se
- Page 59 and 60:
• Avoid running cable next to noi
- Page 61 and 62:
Unit Amps VA VAC Centertapped? 16AI
- Page 63 and 64:
ECT MODBUS The RS485 Network and Ha
- Page 65 and 66:
6 6 SHIELDED TWISTED PAIR BELDEN #8
- Page 67 and 68:
SHIELDED TWISTED PAIR BELDEN #8761.
- Page 69:
I/O NET POWER AC1 GND AC2 JP2 JP3 J
- Page 72 and 73:
7.3 Software Specifications TCP/IP
- Page 74 and 75:
a unique site name in the Group Nam
- Page 76 and 77:
RECOMMENDED E2 E2 UNBROKEN CHAIN Fi
- Page 78 and 79:
2. Use a transformer that has a pow
- Page 80 and 81:
8-6 • E2 RX/BX/CX I&O Manual 026-
- Page 82 and 83:
8-8 • E2 RX/BX/CX I&O Manual 026-
- Page 84 and 85:
S2 1 ON S1 1 ON 2 2 3 3 4 INPUTS 1-
- Page 86 and 87:
P/N Sensor 203-5751 Wall-mounted re
- Page 88 and 89:
550-2500 550-2550 P/N Sensor Table
- Page 90 and 91:
Figure 9-6 - Analog Input Screen Bo
- Page 92 and 93:
input by tying it to OIL RESET 1. T
- Page 94 and 95:
Figure 9-9 - Relay Output Test Mode
- Page 96 and 97:
Figure 9-12 - Digital Output Screen
- Page 98 and 99:
9.3 CC-100 Case Controllers 9.3.1 I
- Page 100 and 101:
Wire on Valve Cable 335-3260 Pin #
- Page 103 and 104:
10 Quick Start This section covers
- Page 105 and 106:
10.4 Setting Number of Applications
- Page 107 and 108:
TIP: To see different messages the
- Page 109 and 110:
10.7.4 The Setup Screens Figure 10-
- Page 111 and 112:
10.8 Time/Date Setup Figure 10-14 -
- Page 113 and 114:
3. Press � (Modem Setup) to advan
- Page 115 and 116:
10.12 Set Up User Access Access the
- Page 117 and 118:
10.13 Set Up I/O Network Figure 10-
- Page 119 and 120:
ESR8 Line Up Boards Enter the numbe
- Page 121 and 122:
five seconds. 10.14.2.2 The Manual
- Page 123 and 124:
the firmware. • View global data
- Page 125 and 126:
10.16.3 Alarm Dial-Out Figure 10-40
- Page 127 and 128:
value until the primary provider ag
- Page 129 and 130:
parameter stored inside the control
- Page 131 and 132:
11 Software Overview 11.1 Suction G
- Page 133 and 134:
CIRCUIT CASE TEMP (FOR FLOATING) CA
- Page 135 and 136:
AMBIENT TEMP INLET PUMP 1 PUMP 2 WA
- Page 137 and 138:
will turn the Defrost output ON to
- Page 139 and 140:
Figure 11-5 - Typical Case in a Sta
- Page 141 and 142:
ming and viewing status. (The EC-2
- Page 143 and 144:
defined Pump Down and Run-Off times
- Page 145 and 146:
Clean Modes may be either fixed or
- Page 147 and 148:
olution (how precisely the analog v
- Page 149 and 150:
11.5.5.1 Logging Group Report The L
- Page 151 and 152:
ters. Whether in Continuous or Auto
- Page 153 and 154:
comfortably within the range of the
- Page 155 and 156:
11.7.2 How Zones Work A Zone is bui
- Page 157 and 158:
11.7.8 The Effect of Enabling Econo
- Page 159 and 160:
Figure 11-18 - Zone Association Scr
- Page 161 and 162:
state, when both the light level st
- Page 163 and 164:
longer than the programmed proof de
- Page 165 and 166:
significant effect on the system if
- Page 167 and 168:
loads. 11.11.6.1 Power Monitoring I
- Page 169 and 170:
eing sent to the outputs, replacing
- Page 171 and 172:
stant period of time that consists
- Page 173 and 174:
NOTE: If you do not wish to use loa
- Page 175 and 176:
drops to the Unoccupied Heating Set
- Page 177 and 178:
must be used. A Multiple Input cell
- Page 179 and 180:
total accumulation, and the last ac
- Page 181 and 182:
11.21.5.1 Bypass Failsafe While eac
- Page 185 and 186:
12 Operator’s Guide to Using the
- Page 187 and 188:
12.3 Toggling Full Options Toggling
- Page 189 and 190:
defrosting can be initiated from th
- Page 191 and 192:
screen, allowing you to change thei
- Page 193 and 194:
cuit Bypass screen opens. Figure 12
- Page 195 and 196:
The E2 BX controller has four statu
- Page 197 and 198:
acknowledged. TIPS: ACKNOWLEDGEMENT
- Page 199 and 200:
12.11.1.2 Setup Screens Figure 12-2
- Page 201:
Pressing � again zooms in even fa
- Page 204 and 205:
Set- High Low Defrost Type Elec. Ty
- Page 207 and 208:
Appendix C: Alarm Advisory Messages
- Page 209 and 210:
Alarm Name Default Priority Comb Te
- Page 211 and 212:
Alarm Name Default Priority Definit
- Page 213 and 214:
Alarm Name Default Priority Definit
- Page 215 and 216:
Alarm Name ISD Discharge Pressure L
- Page 217 and 218:
Alarm Name Default Priority Definit
- Page 219 and 220:
Alarm Name Default Priority RX/BX F
- Page 221 and 222:
Appendix D: PID Control Introductio
- Page 223 and 224:
TEMPERATURE Figure D-2 - Comparison
- Page 225 and 226:
CONTROL INPUT THROTTLING RANGE OUTP
- Page 229 and 230:
Appendix E: Compressed Point Log Sa
- Page 231 and 232:
Appendix F: Troubleshooting The cha
- Page 233 and 234:
SYMPTOM POSSIBLE PROBLEM SOLUTION C
- Page 235 and 236:
SYMPTOM POSSIBLE PROBLEM SOLUTION P
- Page 237 and 238:
SYMPTOM POSSIBLE PROBLEM SOLUTION P
- Page 241 and 242:
Index Numerics 16AI Analog Input Bo
- Page 243 and 244:
EEPRs 11-12 EEVs 11-11 sensor defau
- Page 245 and 246:
wire restrictions 8-3 wiring 8-1 wi
- Page 247 and 248:
Logs and Graphs 12-14 LonMark Devic
- Page 249 and 250:
alarm control 11-37 combiner functi
- Page 251:
See Jumpers, termination. Thermosta