3.1.4 Blank Face<br />

Blank face control is designed to be used in a system<br />

with more than one <strong>E2</strong>. It has no screen or keyboard and is<br />

logged into remotely from another <strong>E2</strong> on the Echelon network.<br />

The green General Status LED transmits status<br />

information to the user. See Table 2-3 on page 2-3 for<br />

more information on main board (CPU) status LEDs.<br />

Blank face mounting dimensions are identical to the standard<br />

and recessed mount boxes. See Figure 3-3 and Figure<br />

3-4.<br />

3.2 Mounting I/O Boards<br />

The 16AI, 8RO, 8DO, 4AO, 8IO, and MultiFlex<br />

boards are usually installed by the refrigeration or building<br />

equipment manufacturer. Therefore, the installer need only<br />

make the necessary connections between the <strong>E2</strong> and the<br />

cases, condenser boards, and/or HVAC units.<br />

In some instances, an installer may be required to<br />

mount an I/O board. There are no restrictions on the location<br />

of these boards; however, for ease of network configuration,<br />

it is recommended that the boards be located<br />

adjacent to the <strong>E2</strong>. I/O boards may be mounted without an<br />

enclosure, but they should be mounted in a location that is<br />

not easily accessible to avoid tampering or damage.<br />

3.2.1 Single/Double Enclosures<br />

The Single enclosure and Double enclosure are supplied<br />

with four mounting holes in the rear panel of the<br />

enclosure. The mounting holes can be accessed without<br />

removing any of the boards inside the enclosure. Figure 3-<br />

7 shows the dimensions and weight for the Single enclosure.<br />

Figure 3-8 shows mounting dimensions for the Double<br />

enclosure. When mounting boards inside the<br />

enclosure, refer to Figure 3-9 for mounting dimensions<br />

for the MultiFlex, 16AI, 8RO, and the 8DO.<br />

Figure 3-7 - Single Enclosure Mounting Dimensions<br />

Figure 3-8 - Double Enclosure Mounting Dimensions<br />

Mounting I/O Boards Mounting • 3-3