13.07.2015 Views

Series SYJ3000/5000/7000 - SMC Pneumatics (Ireland)

Series SYJ3000/5000/7000 - SMC Pneumatics (Ireland)

Series SYJ3000/5000/7000 - SMC Pneumatics (Ireland)

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

For details about certified productsconforming to international standards,visit us at www.smcworld.com.265 Port Solenoid ValveRubber Seal<strong>Series</strong> SYJ<strong>5000</strong>SpecificationsJIS SymbolBody ported2 position single(A)(B)4 25 1 3(R1)(P)(R2)2 position double(A)(B)4 25 1 3(R1)(P)(R2)3 position closed center(A)(B)4 25 1 3(R1)(P)(R2)3 position exhaust center(A)(B)4 25 1 3(R1)(P)(R2)3 position pressure center1-5-26(A)(B)4 25 1 3(R1)(P)(R2)Body portedBase mountedBase mounted (with sub-plate)2 position single(B)(A)2 43 1(R)(P)2 position double(B)(A)2 43 1(R)(P)3 position closed center(B)(A)2 43 1(R)(P)3 position exhaust center(B)(A)2 43 1(R)(P)3 position pressure center(B)(A)2 43 1(R)(P)Made to Order Specifications(For details, refer to pages 1-5-72 to 73.)Fluid2 position singleOperating pressure rangeMPa2 position double3 positionAmbient and fluid temperature (°C)Response time (ms)(at 0.5 MPa)Max. operating frequency(Hz)Note 1)Manual override (Manual operation)Pilot exhaust methodLubricationMounting orientationShock/Vibration resistance (m/s 2 )EnclosureNote 2)Solenoid SpecificationsElectrical entryCoil rated voltage (V)Allowable voltage fluctuationPower consumption (W)Apparent power VA ∗Surge voltage suppressorIndicator light2 position single, double3 position2 position single, double3 positionBuilt-in Speed ControllerSYJ55StandardWith power saving circuit100V110V[115V]200V220V[230V] Built-in exhaust flow controls enable simple cylinderspeed adjustments. When mounted on the manifold, the common exhaustdischarges the pilot and main valve exhaust through acommon EXH port to enable simple exhausting.(B)JIS Symbol2 (A)4(Single)How to order valve with built-in speed controllerSYJ5 5 – –Type ofactuationBody optionRated voltageLead wire3(R)(P)1DCAC 50/60 HzDCACPort sizeManual overrideLight/Surge voltage suppressorAir0.15 to 0.70.1 to 0.70.15 to 0.7–10 to 50 (No freezing. Refer to page 1-7-4.)25 or less40 or less53Non-locking push type, push-turn locking slotted type, push-turn locking lever typeIndividual exhaust for the pilot valve, common exhaust for the pilot and main valveNot requiredUnrestricted150/30Dustproof (∗ DIN terminal, M8 connector conforms to IP65.)∗ Based on IEC529Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage, without surge suppressor)Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles tothe main valve and armature in both energized and de-energized states every once for each condition.(Value in the initial state)Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and rightangle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state)Grommet (G), (H), L plug connector (L)M plug connector: (M), DIN terminal (D)M8 connector (W)24, 12, 6, 5, 3100, 110, 200, 220±10% of rated voltage0.35 {With light: 0.4 (DIN terminal with indicator light: 0.45)}0.1 (With indicator light only)1.4 (With indicator light: 1.5)1.6 (With indicator light: 1.7)[1.7 (With indicator light: 1.8)]2.3 (With indicator light: 2.4)2.5 (With indicator light: 2.6)[2.7 (With indicator light: 2.8)]Diode (DIN terminal, varistor when non-polar types)LED (Neon light when AC with DIN terminal)∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.AThrottle Valve Characteristics ( R)Effective area (mm 2 )210(Fully 1 2 3 4 5 6 7 (Fullyclosed)open) When using SYJ553 model the speed controllermust be opend more than 1 complete rotation fromfully closed in order to function proerly. Adjust the speed controller with a torque of 0.3 N mor less.Plate fixing screwNote) Do not loosen plate fixing screw.B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!