For details about certified productsconforming to international standards,visit us at www.smcworld.com.505 Port Solenoid ValveRubber Seal<strong>Series</strong> SYJ<strong>7000</strong>SpecificationsJIS SymbolBody ported2 position single(A)(B)4 25 1 3(R1)(P)(R2)2 position double(A)(B)4 25 1 3(R1)(P)(R2)3 position closed center(A)(B)4 25 1 3(R1)(P)(R2)3 position exhaust center(A)(B)4 2Body portedBase mountedBase mounted2 position single solenoid(B)2 (A)43 1 5(R2)(P)(R1)2 position double solenoid(B)2 (A)43 1 5(R2)(P)(R1)3 position closed center(B)2 (A)43 1 5(R2)(P)(R1)3 position exhaust center(B)2 (A)4FluidOperating pressure rangeMPa3 positionAmbient and fluid temperature (°C)Response time (ms)Note 1)(at 0.5 MPa)Max. operating frequency(Hz)Manual override (Manual operation)Pilot exhaust methodLubricationMounting orientationShock/Vibration resistance (m/s 2 )Enclosure2 position single2 position double2 position single, double3 position2 position single, double3 positionNote 2)Solenoid SpecificationsElectrical entryCoil rated voltage (V)Allowable voltage fluctuationPower consumption (W)Apparent power VA ∗Surge voltage suppressorIndicator lightDCAC 50/60 HzDCACStandardWith power saving circuit100V110V[115V]200V220V[230V]Air0.15 to 0.70.1 to 0.70.15 to 0.7–10 to 50 (No freezing. Refer to page 1-7-4.)30 or less60 or less53Non-locking push type, push-turn locking slotted type, push-turn locking lever typeIndividual exhaust for the pilot valve, common exhaust for the pilot and main valveNot requiredUnrestricted150/30Dustproof (∗ DIN terminal, M8 connector conforms to IP65.)∗ Based on IEC529Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage,without surge suppressor)Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axialdirection and at the right angles to the main valve and armature in bothenergized and de-energized states every once for each condition.(Value in the initial state)Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Testwas performed to axis and right angle directions of the main valve andarmature when pilot signal is ON and OFF. (Value in the initial state)Grommet (G), (H)L plug connector (L)M plug connector (M)DIN terminal (D)M8 connector (W)24, 12, 6, 5, 3100, 110, 200, 220±10% of rated voltage0.35 {With light: 0.4 (DIN terminal with indicator light: 0.45)}0.1 (With indicator light only)1.4 (With indicator light: 1.5)1.6 (With indicator light: 1.7)[1.7 (With indicator light: 1.8)]2.3 (With indicator light: 2.4)2.5 (With indicator light: 2.6)[2.7 (With indicator light: 2.8)]Diode (DIN terminal, varistor when non-polar types)LED (Neon light when AC with DIN terminal)∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.5 1 3(R1)(P)(R2)3 position pressure center(A)(B)4 23 1 5(R2)(P)(R1)3 position pressure center(B)2 (A)45 1 3(R1)(P)(R2)3 1 5(R2)(P)(R1)Made to Order Specifications(For details, refer to pages 1-5-72 to 73.)1-5-50

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!