13.07.2015 Views

Series SYJ3000/5000/7000 - SMC Pneumatics (Ireland)

Series SYJ3000/5000/7000 - SMC Pneumatics (Ireland)

Series SYJ3000/5000/7000 - SMC Pneumatics (Ireland)

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Series</strong> SYJ<strong>5000</strong>38Flat Ribbon Cable Manifold Multiple valve wiring issimplified through the use ofthe flat cable connector. Clean appearanceIn the case of a flat ribbon cable type, eachvalve is wired on the print board ofmanifold base to allow the external wiringto be piped all together with 26 pins MILconnector.Flat Ribbon Cable Manifold SpecificationsModelManifold typeP (SUP), R (EXH)Valve stationsA, B portPorting specificationsPort sizeApplicable flat ribbon cableconnectorInternal wiringType 20 Type 41P Type 43PSingle base/B mountCommon SUP, Common EXH3 to 12 stationsLocationDirectionP, R portValveTop1/8BaseSide1/8A, B portM5 x 0.8,C4C4 (One-touch fitting for ø4) M5 x 0.8C6 (One-touch fitting for ø6)(One-touch fitting for ø4)Socket: 26 pins MIL type with strain relief(MIL-C-83503)In common between +COM and –COM (Z type: +COM only)Rated voltage24, 12 VDC/100, 110 VACNote) The withstand voltage specification for the wiring unit section conforms to JIS C 0704, Grade 1 or itsequivalent.Flow CharacteristicsPort sizeManifold1(P), 5/3(R) 2(B), 4(A) CbPort Port [dm 3 /(s·bar)]1/8 M5 x 0.8 0.46 0.39Body portedSS5YJ5-20P1/8for internal pilotSYJ523C4 0.62 0.331/8 C6 0.79 0.36Base mounted SS5YJ5-41P1/8 M5 x 0.8 0.59 0.35SYJ543for internal pilot SS5YJ5-43P1/8 C4 0.55 0.29Note) Value at manifold base mounted, 2 position single operatingFlow characteristics14/2 (PA/B) 4/25/3 (A/BR)Cv0.120.160.210.160.14C[dm 3 /(s·bar)]0.750.830.910.680.74b0.320.270.360.230.32Cv0.190.200.240.170.19How to Order Valves12345NilDE1-5-38For DC:For AC:Type of actuationSYJ52 position single2 position double3 position closed center3 position exhaust center3 position pressure center13SYJ5Non-locking push typePush-turn locking slotted typePush-turn locking lever type100 VAC110 VAC (115 VAC)Manual overrideHow to Order Manifold (Example)Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold alongwith the manifold base model no.Example:∗ Use manifold specification sheet.SS5YJ5-41P-07-C4 ··········· 1 pc. (Manifold base)∗ SYJ5143-5LOU ··················· 3 pcs. (Valve)∗ SYJ5243-5LOU ··················· 3 pcs. (Valve)∗ SYJ<strong>5000</strong>-21-3A ··················· 1 pc. (Blanking plate assembly)∗ SY3000-37-28A ··················· 3 pcs. (Connector assembly)∗ SY3000-37-29A ··················· 3 pcs. (Connector assembly)The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.How to Order Connector AssemblyRated voltage Light/Surge voltage suppressor 12, 24 VDC5 24 VDC Z With light/surge voltage suppressor Single solenoidSY3000-37-28A6 12 VDC U With light/surge voltage suppressor (Non-polar type) Double solenoid, 3 position type SY3000-37-29ANote) Z: Positive common specifications only. Single solenoid, individual SUP, EXH spacer SY3000-37-3A1 2 43 5 LO ZDouble solenoid, 3 position individual SUP/EXH spacer SY3000-37-4AInterface regulator for single solenoid SY3000-37-3ADouble solenoid, 3 position interface regulator SY3000-37-6A1 2 43 1 LOZ3 port adaptor plate SY3000-37-3A100 VACSingle solenoidSY3000-37-46ADouble solenoid, 3 position type SY3000-37-47ASingle solenoid, individual SUP, EXH spacer SY3000-37-32AA, B port sizeDouble solenoid, 3 position individual SUP/EXH spacer SY3000-37-33ASymbol Port sizeInterface regulator for single solenoid SY3000-37-15ANil Base mountedDouble solenoid, 3 position interface regulator SY3000-37-34ARated voltageM5 M5 x 0.83 port adaptor plate SY3000-37-32AC4 One-touch fitting for ø4 100 VAC (115 VAC)C6 One-touch fitting for ø6 Single solenoidSY3000-37-54AN3 One-touch fitting for ø5/32" Double solenoid, 3 position type SY3000-37-55AN7 One-touch fitting for ø1/4"Single solenoid, individual SUP, EXH spacer SY3000-37-35ANote) In the case of flat cable type, “U” and “Z” Double solenoid, 3 position individual SUP/EXH spacer SY3000-37-36Atypes are for DC specifications and “Z” Interface regulator for single solenoid SY3000-37-19Atype is for AC specifications. “Z” type forDouble solenoid, 3 position interface regulator SY3000-37-37ADC is positive common specificationonly. For the ohter combination, please 3 port adaptor plate SY3000-37-35Acontact <strong>SMC</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!