13.07.2015 Views

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INSTALLATION REQUIREMENTSHeat ResistantMaterial10” <strong>or</strong> Less12”Min.28”DEB <strong>Unvented</strong> <strong>Gas</strong> <strong>Log</strong>sThe gas log heater must be installed at least 5" above anycombustible flo<strong>or</strong>ing material, such as carpeting <strong>or</strong> tile,which is closer than 14" to the base of the fireplace. Theminimum distance must be maintained from the top surfaceof carpeting, tile, etc. Figure 11OR,The gas log heater may be installed nearer to the flo<strong>or</strong> if aminimum of 14" of noncombustible material such as slate<strong>or</strong> marble is installed between the base of the fireplace andthe combustible flo<strong>or</strong>ing. Figure 12Fp2799mantel no hood 24<strong>Heater</strong> in Fireplace<strong>or</strong> FireboxFP2799Example: Thebottom of themantel may projectfrom the wall amaximum of 10" ata minimum of 28"above the opening.Figure 9 -DEB24/30 Minimum Mantel Clearance with No HoodMantel7”6”FP2876<strong>Heater</strong> inFireplace <strong>or</strong>Firebox5” MinimumFP2876combustible flo<strong>or</strong>CombustibleMaterialFigure 11 -Minimum Clearance above Combustible Flo<strong>or</strong>ingMinimum of 8”Heat ResistantMaterial2”4”8”14”This DistanceMay Now beLess than 5”<strong>Heater</strong> inFireplace <strong>or</strong>Firebox14” MinimumCombustibleMaterialFP2800HoodFigure 10 -DEB24/30 Example of Unsafe FP2800 Installation - MinimumMantel Clearance with bad No mantel HoodFigure 10 is an example of an unsafe mantel installation.This mantel projects 4" at 8" above the opening,exceeding the maximum acceptable distance of 2Z\x" Themantel also projects 7" at 14Z\x" above the opening, exceedingthe maximum acceptable distance of 6".If your mantel profile is unsafe, you may either:• Raise the mantel to an acceptable height<strong>or</strong>• Remove the mantelFigure 12 -Minimum Clearance above Combustible Flo<strong>or</strong> with NoncombustibleMaterial Installed at Base of FireplaceFP2802non combustible flo<strong>or</strong>44D0060 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!