13.07.2015 Views

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DEB <strong>Unvented</strong> <strong>Gas</strong> <strong>Log</strong>sThe initial break-in operation should last two to threehours with the burner at the highest setting. Providemaximum ventilation by opening windows <strong>or</strong> do<strong>or</strong>s toallow od<strong>or</strong>s to dissipate. Any od<strong>or</strong>s remaining after thisinitial break-in period will be slight and will disappearwith continued use.20. Input ratings are shown in BTU per hour and are f<strong>or</strong>elevations up to 2,000 feet. F<strong>or</strong> elevations above 2,000feet, input ratings should be reduced 4 percent f<strong>or</strong> each1,000 feet above sea level. Refer to the National Fuel<strong>Gas</strong> Code.21. The appliance and its appliance main gas valve mustbe disconnected from the gas supply piping systemduring any pressure testing of that system at test pressuresin excess of 1/2 psig (3.5 kPa).22. The appliance must be isolated from the gas supplypiping system by closing its equipment shutoff valveduring any pressure testing of the gas supply pipingsystem at test pressures equal to <strong>or</strong> less than 1/2 psig(3.5 kPa).23. Do not use this room heater if any part has been underwater. Immediately call a qualified service technicianto inspect the room heater and to replace any part ofthe control system and any gas control which has beenunder water.24. This appliance must not be used with glass do<strong>or</strong>s inthe closed position. This can lead to pilot outages andsevere sooting outside the fireplace.25. Never burn solid fuels in a fireplace where a unventedroom heater is installed.26. Always have a fireplace screen in place when theappliance is in operation and, unless other provisionsf<strong>or</strong> combustion air are provided, the screen must havean opening(s) f<strong>or</strong> induction of combustion air.WARNINGIMPORTANT SAFETY INFORMATIONNever connect unit to private (non-utility)gas wells. This gas is commonly knownas wellhead gas.Nous recommandons que nosappareils de chauffage au gazsoient installés et entretenus pardes professionnels qui ont étéaccrédités aux È.U. par le NationalFireplace Institute ® (NFI) commeétant des spécialistes du NFI enmatièred’appareils de chauffageau gaz.CODESAdhere to all local codes <strong>or</strong>, in their absence, the latest edition of THE NATIONAL FUEL GAS CODEANSI Z223.1 <strong>or</strong> NFPA54 which can be obtained from…American National Standards Institute, Inc.1430 BroadwayNew Y<strong>or</strong>k, NY 10018<strong>or</strong>National Fire Protection Association, Inc.Batterymarch ParkQuincy, MA 0226944D0060

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!