13.07.2015 Views

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

Manual - Unvented Gas Log Heater or Vented Decorative Appliance

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INSTALLATIONAssembly procedure:1. Center the gas log unit in the fireplace <strong>or</strong> firebox. Makecertain the front feet of the grate sit inside the front edgeof the fireplace <strong>or</strong> firebox.2. Anch<strong>or</strong> holes are located on the right and left sides ofthe unit. After centering the grate c<strong>or</strong>rectly, mark thehole positions on the fireplace/firebox flo<strong>or</strong>. Drill two (2)B\cx" diameter holes approximately 1Z\x" deep.3. Anch<strong>or</strong> the grate to the fireplace/firebox flo<strong>or</strong> using thescrews provided. Figure 14Proper installation of the grate is essential to preventany movement of the gas logs and controls duringoperation.ScrewsCONNECT THE GASDEB <strong>Unvented</strong> <strong>Gas</strong> <strong>Log</strong>sNOTICE: A qualified gas appliance installer must connectthe heater to the gas supply. Consult all local codes.CAUTIONUse new black iron <strong>or</strong> steel pipe. Internallytinned copper <strong>or</strong> copper tubing can beused per National Fuel Code, section 2.6.3,providing gas meets hydrogen sulfidelimits, and where permitted by local codes.<strong>Gas</strong> piping system must be sized to provideminimum inlet pressure (Listed on DataPlate) at the maximum flow rate (BTU/Hr).Undue pressure loss will occur if the pipeis too small.A manual shutoff valve must be installedupstream of the appliance. Union teeand plugged 1/8" NPT pressure tappingpoint should be installed upstream of theappliance. Figure 15StainlessFlexibleTubePipeTo<strong>Heater</strong>ValvePossible Locationsf<strong>or</strong> PressureTapping PointFP2803PipeCoupling<strong>Gas</strong>SupplyInletFP2877DEB secure to flo<strong>or</strong>Anch<strong>or</strong>HolesFigure 14 -Secure <strong>Heater</strong> to Flo<strong>or</strong> of Fireplace <strong>or</strong> Firebox<strong>Manual</strong> ShutoffValveFigure 15 -<strong>Gas</strong> ConnectionWARNINGFP2371gas connectFP2371CHECK GAS TYPE: The gas supply mustbe the same as stated on the heater’s ratingplate. If the gas supply is different, DONOT INSTALL THE HEATER. Contact yourdealer f<strong>or</strong> the c<strong>or</strong>rect model.WARNINGConnecting directly to an unregulated propane/LPGtank can cause an explosion.Always use an external regulat<strong>or</strong> f<strong>or</strong> all propane/LPGheaters and high pressure one to two-pound systemsonly, to reduce the supply tank pressure to a maximum of13" w.c. This is in addition to the internal regulat<strong>or</strong> in theheater valve.44D0060 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!