13.07.2015 Views

Amendment No. 1 to MoRTH/CMVR/TAP-115/116

Amendment No. 1 to MoRTH/CMVR/TAP-115/116

Amendment No. 1 to MoRTH/CMVR/TAP-115/116

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7.2.2.3.2. Verification of chassis dynamometer7.2.2.3.2.1. Immediately after the initial setting, the coast down time on the chassis dynamometercorresponding <strong>to</strong> the specified speed shall be measured. The mo<strong>to</strong>rcycle shall not beset up on the chassis dynamometer during the coast down time measurement. Whenthe chassis dynamometer speed exceeds the maximum speed of the test cycle, thecoast down time measurement shall start.7.2.2.3.2.2. The measurement shall be carried out at least three times, and the mean coast downtime tE shall be calculated from the results.7.2.2.3.2.3. The set running resistance force FE(vj) at the specified speed on the chassisdynamometer is calculated by the following equation:FEvj13.6 m i2ΔvΔtEEquation 7-157.2.2.3.2.4. The setting error at the specified speed is calculated by the following equation:ε FEvjFT FT100Equation 7-167.2.2.3.2.5. The chassis dynamometer shall be readjusted if the setting error does not satisfy thefollowing criteria:ε ≤ 2 per cent for v ≥ 50 km/hε ≤ 3 per cent for 30 km/h ≤ v < 50 km/hε ≤ 10 per cent for v < 30 km/h7.2.2.3.2.6. The procedure described above shall be repeated until the setting error satisfies thecriteria. The chassis dynamometer setting and the observed errors shall be recorded.An example of the record form is given in Annex 10.7.2.3. Calibration of analysers7.2.3.1. The quantity of gas at the indicated pressure compatible with the correct functioningof the equipment shall be injected in<strong>to</strong> the analyser with the aid of the flow metre andthe pressure-reducing valve mounted on each gas cylinder. The apparatus shall beadjusted <strong>to</strong> indicate as a stabilized value the value inserted on the standard gascylinder. Starting from the setting obtained with the gas cylinder of greatestcapacity, a curve shall be drawn of the deviations of the apparatus according <strong>to</strong> thecontent of the various standard cylinders used. The flame ionisation analyser shallbe recalibrated periodically, at intervals of not more than one month, usingair/propane or air/hexane mixtures with nominal hydrocarbon concentrations equal <strong>to</strong>50 per cent and 90 per cent of full scale.7.2.3.2. <strong>No</strong>n-dispersive infrared absorption analysers shall be checked at the same intervalsusing nitrogen/C0 and nitrogen/CO 2 mixtures in nominal concentrations equal <strong>to</strong> 10,40, 60, 85 and 90 per cent of full scale.7.2.3.3. To calibrate the NO X chemiluminescence analyser, nitrogen/nitrogen oxide (NO)mixtures with nominal concentrations equal <strong>to</strong> 50 per cent and 90 per cent of fullscale shall be used. The calibration of all three types of analysers shall be checked

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!