Remote operation and fault indication via external LEDs (with ECCM control only)Assuming external LEDs are connected to the respective terminals of the ECCM control unit the followingstates of operation can be displayed remotely:Operation statusOutput activatedon ECCM control unitDisplay on ECCM control unit“Error”, Humidification off H1 “Error” red LED lights upSteam cylinder maintenance due H2 “Maintenance” yellow LED lights upSteam production H3 “Steam production” green LED lights up6.4 Switching offIn order to switch off the steam humidifier, e.g. for maintenance work, take the following steps:• Close shut-off valve to the water feed.• Press drain/info key briefly. The heating voltage is cut off and the steam cylinder empties. Theyellow LED blinks (only on units equipped with ECCM control).• Wait until the steam cylinder is empty (approx. 5-10 minutes). Then switch off the unit via theOn/Off switch and secure switch in “off” position against accidentally being switched on.• Disconnect steam humidifier from electricity supply: Switch off all service switches to networksupplies (heating and control voltage) and secure switch in “off” position against accidentallybeing switched on.34