SHEET DP003FAILURE DETECTION FLOW CHARTNO UP MOVEMENT FROM THECH<strong>AS</strong>SIS OR PLATFORM CONTROLSheet 3/4BInput(27)at +24VNOCheck operation of tilt detector SQ10 :- Check supply, connection- Check operation- Check the settingYESInput (29)at +24VNOReplace theconnector or thetilt detectorSeeSHEETC006YESInput(25) at +24V(below 1.5mor 4ft92in)NOENDYESInput(24) at +24VYESNOCheck operation of the end of strokecontactor SQ3:- Check supply, connection- Check operation- Check settingReplace the speedvariator U1See SHEETC003ENDCheck operation of end of strokecontactors SQ1, SQ5 and SQ6:- Check supply, connection- Check operation- Check settingAdjust or replace thedefective detector or itswiringSee SHEETC018END