MULTIPORT FUEL INJECTION (MFI)13A-63MULTIPORT FUEL INJECTION (MFI) DIAGNOSISCONNECTOR: C-115STEP 3. Measure the sensor output voltage at ECMconnector C-115 by backprobing.(1) Do not disconnect connector C-115.(2) Turn the ignition switch to the "ON" position.HARNESS C-115 (Y)CONNECTOR:COMPONENT SIDE8180 79 78 77 76 75 74 73 72 7192 9190 89 88 87 86 85 84 83 82AK203645ABC-115 HARNESS CONNECTOR: HARNESS SIDEAK000281AH(3) Measure the voltage between terminal No. 85 and groundby backprobing.• When altitude is 0 m (0 foot), voltage should measure3.7 and 4.3 volts.• When altitude is 600 m (1,969 feet), voltage shouldmeasure 3.4 and 4.0 volts.• When altitude is 1,200 m (3,937 feet), voltage shouldmeasure 3.2 and 3.8 volts.• When altitude is 1,800 m (5,906 feet), voltage shouldmeasure 2.9 and 3.5 volts.(4) Turn the ignition switch to the "LOCK" (OFF) position.Q: Is the measured voltage within the specified range?YES : Go to Step 4.NO : Go to Step 6.TSB Revision