13.07.2015 Views

Tab 36

Tab 36

Tab 36

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Adjustable Frequency DrivesH-Max Series Drives<strong>36</strong>.5H-Max IntelliPass/IntelliDisconnectPrimary Design FeaturesDescription IntelliPass IntelliDisconnect Description IntelliPass IntelliDisconnectCB MMP Standard Standard Isolation switch Optional N/A2 contactor bypass Standard N/A Top entry (power) Standard StandardMechanical interlock Standard N/A Bottom entry (power) Standard StandardElectrical interlock Standard N/A Output contactor Standard OptionalThird contactor (isolation) Optional N/ATechnical Data and SpecificationsH-Max Series DrivesDescriptionSpecificationInput RatingsInput voltage (V in ) 208, 230, 480 Vac, –10%/+10%Input frequency (f in ) 50/60 Hz (variation up to 47–66 Hz)Connection to power Once per minute or less (typical operation)Short circuit withstand 65 kAIC combinationratingOutput RatingsOutput voltage0 to V in /U in line voltage inContinuous output current Ambient temperature max. 104°F (40°C)I L overload1.1 x I L (1 min./10 min.)Overload current110% (1 min./10 min.)Initial output current 150% for two secondsOutput frequency0 to 320 HzFrequency resolution 0.01 HzControl CharacteristicsControl methodFrequency control (V/f) open loop sensorless vector controlSwitching frequency 1–310 amps; adjustable with parameter 2.6.9FS4–FS7: default 6 kHzFrequency reference Analog input: Resolution 0.1% (10-bit), accuracy ±1%Panel reference: Resolution 0.01 HzField weakening point 8 to 320 HzAcceleration time 0.1 to 3000 secondsDeceleration time 0.1 to 3000 secondsBraking torqueDC brake: 30% x T n (without brake option)Ambient ConditionsAmbient operatingtemperatureStorage temperatureRelative humidityFS4–FS7: 14°F (–10°C), no frost to 104°F (40°C)(Drive can operate at 122°F (50°C)–40° to 158°F (–40° to 70°C)0 to 95% RH, noncondensing, non-corrosive, no dripping waterAir quality Chemical vapors: IEC 60721-3-3, unit in operation, Class 3C2;Mechanical particles: IEC 60721-3-3, unit in operation, Class 3S2Altitude100% load capacity (no derating) up to 3280 ft (1000m);1% derating for each 328 ft (100m) above 3280 ft (1000m);max. 9842 ft (3000m); 380–480VVibrationFS4–FS7: EN 61800-5-1, EN 60068-2-6; 5 to 150 Hz,displacement amplitude 1 mm (peak) at 5 to 15.8 Hz,max. acceleration amplitude 1G at 15.8 to 150 HzShockEN 61800-5-1, EN 60068-2-27 UPS Drop test (for applicable UPSweights) Storage and shipping: max. 15G, 11 ms (in package)Enclosure classNEMA Type 1/IP21 or NEMA Type 12/IP54(keypad required for IP54/Type 12)DescriptionStandardsEMCEmissionsControl ConnectionsAnalog input voltageAnalog input currentDigital inputs (6)Auxiliary voltageOutput reference voltageAnalog outputRelay outputsHard wire jumperDip switch setting defaultSpecificationImmunity: Fulfills all EMC immunity requirements;Emissions: EN 61800-3, LEVEL H (EMC C2)EMC level dependent—+EMC 2: EN61800-3 (2004) Category C2Delivered with Class C2 EMC filtering as default.0 to 10V, R = 200 kohms differentialResolution 0.1%; Accuracy ±1%Dip switch selection (voltage/current)0(4) to 20 mA; R i –250 ohms differentialPositive or negative logic; 18 to 30 Vdc+24V ±10%, max. 250 mA+10V +3%, max. load 10 mA0–10V, 0(4) to 20 mA; R L max. 500 ohms;Resolution 10 bit; Accuracy ±2%;Dip switch selection (voltage/current)3 programmable, 2 Form C, 1 Form A relay outputsSwitching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4ABetween terminal 6 and 10 factory defaultRS485 = offA01 = currentA12 = currentA11 = voltageProtectionsOvercurrent protection YesOvervoltage protection YesDC bus regulation anti-trip Yes (accelerates or decelerates the load)Undervoltage protection YesEarth fault protection Yes (in case of earth fault in motor or motor cable,only the frequency converter is protected)Input phase supervision Yes (trips if any of the input phases are missing)Motor phase supervision Yes (trips if any of the output phases are missing)Overtemperature protection YesMotor overload protection YesMotor stall protection YesMotor underload protection YesShort circuit protection YesSurge protectionYes (varistor input)Conformed coated Yes (prevents corrosion)(varnished) boardSeismicOHSPD Special Seismic Certification Pre-Approved<strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong>Volume 6—Solid-State Motor Control CA08100007E—April 2011 www.eaton.comV6-T<strong>36</strong>-155

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!