Adjustable Frequency DrivesCPX9000 Drives<strong>36</strong>.73. Clean Power DrivesWhen the total load is of nonlinear,the greatest harmonicmitigation is required. Underthese conditions, the currentsdrawn from the supply needto be sinusoidal and “clean”such that systeminterference and additionallosses are negligible. Eaton’sCPX9000 clean powerdrive uses a phase-shiftingauto-transformer withdelta-connected winding.Three of the output phasesare advanced and three areretarded. The remaining threephases of this nine-phasesupply are in phase with theincoming line. This results innine separate phases. In thistype of configuration, thetotal required kVA rating ofthe transformer is only 48%of a drive rate isolationtransformer. A traditionalisolated transformer system,with multipulse windings,would require the full kVABasic 18-Pulse Rectifier with Phase Shifting Transformer1233-PhaseAC Input8C796N500 hp 480V Drive with 18-Pulse RectifiersCurrentAmps10005000–500A1518-Pulse SCRBridge RectifierConverter Section218-PulsePhase-ShiftingAuto-Transformer1233 454 6789–10000.126 0.13225 0.1385Time in SecondsDiode Rectifiers0.14475 0.151rating to be supported, whichis more common in an MVstep-down transformer.The integrated 18-pulseclean power drive, withnear sine wave input currentand low harmonics will meetthe requirements of IEEE519-1992 under all practicaloperating conditions. Thecomparisons with six-pulseand 12-pulse systemsare shown, see PagesV6-T<strong>36</strong>-194, V6-T<strong>36</strong>-196and V6-T<strong>36</strong>-197.BusCapacitorsPre-chargeCircuitDynamic BrakingTransistorInverter Section(+) DC(–) DCOutput TransistorsIGBT Section500 hp 480V Drive with 18-Pulse Rectifiers18-Pulse Clean PowerCurrent harmonicsI 1 = 100% I 11 = 0.24% I 19 = 1.00%I 5 = 0.16% I 13 = 0.10% I 23 = 0.01%I 7 = 0.03% I 17 = 0.86% I 25 = 0.01%Power = 500 hpH c = 24 ampsAdvantages● Virtually guaranteescompliance withIEEE 519-1992●Provides increased inputprotection for AFD and itssemiconductors from linetransients●Up to four times theharmonic reduction of12-pulse methods●Smaller transformer thanisolation transformer usedin 12-pulse converterACMotorDisadvantages● Not as cost-effective assome other methods atsmall (

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!