13.07.2015 Views

Tab 36

Tab 36

Tab 36

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>36</strong>.7Adjustable Frequency DrivesCPX9000 Drives<strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong>Technical Data and SpecificationsCPX9000 DrivesDescriptionSpecificationPrimary Design Features45–66 Hz input frequency StandardOutput: AC volts maximumInput voltage baseOutput frequency range0–320 HzInitial output current (I H )250% for 2 secondsOverload (1 minute [I H /I L ]) 150%/110%Enclosure space heaterOptionalOversize enclosureStandardOutput contactorOptionalBypass motor starterOptionalListingsUL, cUL, 508CProtection FeaturesIncoming line fusesStandard 200 kAIC ratingAC input circuit disconnectOptionalPhase rotation insensitiveStandardEMI filterStandard FR6 thru FR9 Input phase loss protectionStandardInput overvoltage protectionStandardLine surge protectionStandardOutput short-circuit protectionStandardOutput ground fault protectionStandardOutput phase protectionStandardOvertemperature protectionStandardDC overvoltage protectionStandardDrive overload protectionStandardMotor overload protectionStandardProgrammer softwareOptionalLocal/remote keypadStandardKeypad lockoutStandardFault alarm outputStandardBuilt-in diagnosticsStandardSurge protective deviceOptionalDescriptionSpecificationInput/Output Interface FeaturesSetup adjustment provisionsRemote keypad/displayStandardPersonal computerStandardOperator control provisionsDrive mounted keypad/displayStandardRemote keypad/displayStandardConventional control elementsStandardSerial communicationsOptional115 Vac control circuit OptionalSpeed setting inputsKeypadStandard0–10 Vdc potentiometer/voltage signal Standard4–20 mA isolated Configurable4–20 mA differential Configurable3–15 psig OptionalAnalog outputsSpeed/frequencyStandardTorque/load/currentProgrammableMotor voltageProgrammableKilowattsProgrammable0–10 Vdc signals Configurable w/jumpers4–20 mA DC signals StandardIsolated signalsStandardDiscrete outputsFault alarmStandardDrive runningStandardDrive at set speedProgrammableOptional parameters 14Dry contacts2 Form C contacts availableAdditional discrete outputsOptionalCommunicationsRS-232StandardRS-422/485OptionalDeviceNetOptionalModbus RTUOptionalCanOpen (slave)OptionalProfibus-DPOptionalLonWorksOptionalJohnson Controls Metasys N2OptionalEthernet IP/Modbus TCPOptionalBACnetOptionalNoteThe EMI filter is optional in FR10 and larger.V6-T<strong>36</strong>-214Volume 6—Solid-State Motor Control CA08100007E—April 2011 www.eaton.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!