13.07.2015 Views

Tab 36

Tab 36

Tab 36

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Adjustable Frequency DrivesCPX9000 Drives<strong>36</strong>.7Modbus RTU NetworkCommunicationsThe Modbus Network CardOPTC2 is used for connectingthe 9000X Drive as a slaveon a Modbus network. Theinterface is connected bya 9-pin DSUB connector(female) and the baud rateranges from 300 to 19,200baud. Other communicationparameters include anaddress range from 1 to 247;a parity of None, Odd orEven; and the stop bit is 1.PROFIBUS NetworkCommunicationsThe PROFIBUS Network CardOPTC3 is used for connectingthe 9000X Drive as a slaveon a PROFIBUS-DP network.The interface is connectedby a 9-pin DSUB connector(female). The baud ratesrange from 9.6K baud to 12Mbaud, and the addressesrange from 1 to 127.LonWorks NetworkCommunicationsThe LonWorks Network CardOPTC4 is used for connectingthe 9000X Drive on aLonWorks network. Thisinterface uses StandardNetwork Variable Types(SNVT) as data types. Thechannel connection isachieved using a FTT-10AFree Topology transceivervia a single twisted transfercable. The communicationspeed with LonWorks is78 kBits/s.CANopen (Slave)CommunicationsThe CANopen (Slave)Network Card OPTC6 is usedfor connecting the 9000XDrive to a host system.According to ISO 11898standard cables to be chosenfor CAN bus should havea nominal impedance of120 ohms, and specific linedelay of nominal 5 nS/m.120 ohm line terminationresistors required forinstallation.DeviceNet NetworkCommunicationsThe DeviceNet Network CardOPTC7 is used for connectingthe 9000X Drive on aDeviceNet Network. Itincludes a 5.08 mm pluggableconnector. Transfer methodis via CAN using a two-wiretwisted shielded cable withtwo-wire bus power cableand drain. The baud ratesused for communicationinclude 125K baud, 250Kbaud and 500K baud.Johnson Controls Metasys N2Network CommunicationsThe OPTC2 fieldbus boardprovides communicationbetween the 9000X Driveand a Johnson ControlsMetasys N2 network.With this connection, thedrive can be controlled,monitored and programmedfrom the Metasys system.The N2 fieldbus is available asa factory-installed option andas a field-installable kit.Modbus/TCP NetworkCommunicationsThe Modbus/TCP NetworkCard OPTCI is used forconnecting the 9000X Driveto Ethernet networks usingModbus protocol. It includesan RJ-45 pluggableconnector. This interfaceprovides a selection ofstandard and custom registervalues to communicate driveparameters. The boardsupports 10 Mbps and100 Mbps communicationspeeds. The IP address ofthe board is configurable overEthernet using a suppliedsoftware tool.BACnet NetworkCommunicationsThe BACnet Network CardOPTCJ is used for connectingthe 9000X Drive to BACnetnetworks. It includes a 5.08mm pluggable connector.Data transfer is Master-Slave/Token Passing (MS/TP)RS-485. This interface usesa collection of 30 BinaryValue Objects (BVOs) and35 Analog Value Objects(AVOs) to communicatedrive parameters. The cardsupports 9.6, 19.2 and 38.4Kbaud communicationspeeds and supports networkaddresses 1 to 127.Ethernet/IP NetworkCommunicationsThe Ethernet/IP NetworkCard OPTCK is used forconnecting the 9000X Driveto Ethernet/IndustrialProtocol networks. It includesan RJ-45 pluggableconnector. The interface usesCIP objects to communicatedrive parameters (CIP is“Common IndustrialProtocol,” the same protocolused by DeviceNet). Theboard supports 10 Mbps and100 Mbps communicationspeeds. The IP address ofthe board is configurableby Static, BOOTP andDHCP methods.<strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong><strong>36</strong>Volume 6—Solid-State Motor Control CA08100007E—April 2011 www.eaton.comV6-T<strong>36</strong>-209

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!