13.07.2015 Views

Bursting and Spalling in Pretensioned U-Beams - Ferguson ...

Bursting and Spalling in Pretensioned U-Beams - Ferguson ...

Bursting and Spalling in Pretensioned U-Beams - Ferguson ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4.2.2.3 Beam 1: Transverse-Bar <strong>Burst<strong>in</strong>g</strong> & <strong>Spall<strong>in</strong>g</strong> Stresses<strong>Burst<strong>in</strong>g</strong> <strong>and</strong> spall<strong>in</strong>g stresses <strong>in</strong> transverse re<strong>in</strong>forcement are shown <strong>in</strong>Figure 4.3. The circles <strong>in</strong> this figure represent stress values, <strong>and</strong> are superimposed onBeam 1 end-region elevations at the location of their associated stra<strong>in</strong> gage. Circle area isproportional to the stress measurement; its color relates the stress measurement to theAASHTO design maximum, 20 ksi. Crack patterns from transfer are also shown on thebeam elevation.Measured stresses were low compared to the AASHTO limit <strong>in</strong> general.Transverse-bar stresses typically decreased with distance from the beam end, even <strong>in</strong> theburst<strong>in</strong>g zone. Reasonable correlation can be seen between the presence of a visible crack<strong>and</strong> the measurement of moderate stresses (at least 8 ksi) or higher. Nevertheless, at somelocations where crack<strong>in</strong>g was noted, stresses were relatively low (e.g. Location 1C,Figure 4.3).For one gage located at the top flange/web junction (Location 1A), stressesexceeded the AASHTO limit (thus is represented by a red dot <strong>in</strong> Figure 4.3). The highstress was measured adjacent to long, wide cracks (20 to 30 <strong>in</strong>., 0.020 <strong>in</strong>.). This crack<strong>in</strong>gwas exacerbated, if not caused, by the large skew. Across the beam width from thislocation (at Location 1D), the prestress<strong>in</strong>g force from the str<strong>and</strong>s was fully transferred tothe section: the provided bond length (90 <strong>in</strong>.) exceeded the transfer length by a factor ofthree. The cracks at the top flange/web junction extended from the top corner of the endblock (at Location 1A), then to run diagonally across the web.The only other location where the measured transverse-bar stress approached theAASHTO limit was mid-depth at the square end of the beam (Location 1E, Figure 4.3).By 1 hour after transfer, read<strong>in</strong>gs from this gage surpassed the 20-ksi limit stress. The155

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!