Evaluation of Septic Tank and Subsurface Wetland for
Evaluation of Septic Tank and Subsurface Wetland for
Evaluation of Septic Tank and Subsurface Wetland for
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Figure 3-7 Retrieve youth in front <strong>of</strong> boys’ toilet building. The concrete structure<br />
to the left is the open air urinal. (Photograph by author.)<br />
All toilets flush through 4-inch PVC pipe into one horizontal 880-US gallon plastic tank<br />
that empties into a vertical 400-gallon plastic tank. This follows the same design as the<br />
Pisgah septic tanks. This system was built with one snorkel pump aerator in the 800gallon<br />
tank that was powered by two solar panels. The aerator was disconnected several<br />
weeks prior to the evaluation. The septic tank effluent flows approximately 50 feet<br />
horizontally with slight downward pitch to the inlet distribution manhole <strong>for</strong> the<br />
wetl<strong>and</strong>s.<br />
22