Evaluation of Septic Tank and Subsurface Wetland for
Evaluation of Septic Tank and Subsurface Wetland for
Evaluation of Septic Tank and Subsurface Wetland for
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
pH<br />
The results <strong>for</strong> the pH tests are presented in Table 5-10. Average pH <strong>of</strong> the influent to<br />
the Pisgah septic system was determined to be 7.3 <strong>and</strong> influent to the Retrieve septic<br />
system was determined to be 7.2. The pH <strong>of</strong> the effluent <strong>of</strong> both systems was consistent<br />
<strong>and</strong> slightly basic at pH <strong>of</strong> 7.5 <strong>for</strong> Pisgah <strong>and</strong> 7.7 <strong>for</strong> Retrieve which is well within the<br />
Jamaican national effluent st<strong>and</strong>ards <strong>for</strong> pH <strong>of</strong> 6 – 9.<br />
Table 5-10 pH <strong>of</strong> Water Samples at Pisgah <strong>and</strong> Retrieve Sanitation Systems<br />
________________________________________________________________________<br />
Sample Arithmetic Mean 90% Confidence Sample<br />
( X ) mg/l Interval mg/l Size (n)<br />
Pisgah First <strong>Septic</strong> <strong>Tank</strong> 7.3 X ± 0.4<br />
5<br />
Pisgah Wetl<strong>and</strong> Influent 7.4 X ± 0.5<br />
5<br />
Pisgah Wetl<strong>and</strong> Effluent 7.7 X ± 0.1<br />
4<br />
Retrieve First <strong>Septic</strong> <strong>Tank</strong> 7.2 X ± 0.3<br />
6<br />
Retrieve Wetl<strong>and</strong> Influent 7.2 X ± 0.3<br />
6<br />
Retrieve Wetl<strong>and</strong> Effluent 7.5 X ± 0.1<br />
7<br />
51