666 221<br />

Hand-held pH meter<br />

For measuring pH, temperature and redox<br />

values. If a temperature sensor (666 241) is<br />

connected, temperature compensations are<br />

carried out automatically; otherwise the temperature<br />

is entered manually on the keypad.<br />

Measurement ranges:<br />

pH: 0 ... 14 pH ±0.05 pH<br />

–1999 ... +1999 mV ±5%<br />

Temperature:<br />

–199.9 ... +199.9 ˚C ±0.5 ˚C (Pt 1000)<br />

–10.0 ... +110.0 ˚C ±0.2 ˚C (NTC)<br />

Input resistance: 10 19 ohm<br />

Inputs: pH DIN socket (DIN 19 262)<br />

DIN socket, 8 pins (for temperature sensor)<br />

Output: DIN socket, 8 pins, serial (RS 232)<br />

Power supply: 9 V battery<br />

667 417<br />

pH single-rod electrode<br />

In unbreakable plastic shaft suitable for outdoor<br />

use, with DIN plug, 13 mm dia.<br />

666 241<br />

Temperature sensor Pt 1000<br />

For temperature measurement and automatic<br />

temperature compensation.<br />

667 415<br />

Redox probe<br />

For oxidation-reduction measurements, with<br />

platinum pin and Ag/AgCl reference system;<br />

with DIN connector, 13 mm dia.<br />

666 222<br />

Hand-held conductivity meter<br />

For measuring the conductivity (conductance)<br />

of solutions. Temperatures are compensated<br />

automatically by the temperature sensor (integrated<br />

in the conductivity measurement cell) or<br />

manually by entering the values. This device<br />

can also be used to measure temperatures.<br />

The conductivity measurement cell is calibrated<br />

by entering the cell constant or with the help of<br />

the calibration solution. The measurement<br />

range can be selected manually or automatically.<br />

Measurement ranges:<br />

Conductivity:<br />

0 ... 19.9 µS ±1%<br />

0 ... 1.999 mS ±1%<br />

0 ... 19.9 mS ±1%<br />

0 ... 199.9 mS ±2%<br />

Temperature:<br />

–10.0 ... +110.0 ˚C ±0.2˚C (NTC)<br />

–199.9 ... +199.9 ˚C ±0.5 ˚C (PT 1000)<br />

Input: DIN socket, 8 pins<br />

Output: DIN socket, 8 pins, serial (RS 232)<br />

Power supply: 9 V battery<br />

666 242<br />

Conductivity measurement cell<br />

With integrated temperature sensor for automatic<br />

temperature compensation<br />

666 224<br />

Hand-held oxygen meter<br />

ecology<br />

This device is used for measuring the absolute<br />

content of oxygen in solutions and the relative<br />

saturation of oxygen. The displayed concentration<br />

of oxygen is corrected automatically for air<br />

pressure and temperature, which can also be<br />

displayed.<br />

Measurement ranges:<br />

0 ... 19.99 mg/l oxygen concentration in<br />

aqueous solutions<br />

0 ... 199.9 % relative saturation in<br />

liquids or air<br />

Temperature: 0 ... 45 ˚C ± 0.5 ˚C<br />

Air pressure: 800 ... 1100 hPa ±10 hPa<br />

Input: DIN socket, 8 pins<br />

Output: DIN socket, 8 pins, serial (RS 232)<br />

Power supply: 9 V battery<br />

667 458<br />

Oxygen electrode<br />

For measuring concentrations of oxygen and<br />

the relative saturation of oxygen. Complete with<br />

an integrated temperature sensor for automatic<br />

temperature compensation, zero-point and<br />

electrolyte solutions for calibrating the<br />

electrode.<br />

667 451<br />

Accessory set for the oxygen electrode<br />

Contains 5 spare caps with membranes.<br />

LEYBOLD DIDACTIC ·GENERAL CATALOGUE CHEMISTRY<br />