General Catalogue Chemistry - BECO Internacional LTDA.
General Catalogue Chemistry - BECO Internacional LTDA.
General Catalogue Chemistry - BECO Internacional LTDA.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
analysis methods<br />
Butane gas analysis by thermal decomposition<br />
667 400<br />
667 400<br />
Combustion chamber<br />
for quantitative synthesis of water<br />
667 403<br />
A capillary tube is used to direct the hydrogen<br />
to the arc, where it burns in the atmosphere.<br />
The gases used here are introduced into the<br />
reaction vessel under slight pressure by means<br />
of gas syringes, thus permitting quantitative<br />
analyses. The water created here condenses<br />
on the chamber wall and is clearly visible. The<br />
combustion chamber itself is so light in weight<br />
as to allow for gravimetric determination of its<br />
mass. When 50 ml of H 2 and 25 ml of O 2 are<br />
consumed one can detect an increase in<br />
weight of exactly 20.0 mg (at standard temperature<br />
and pressure).<br />
Application examples<br />
· Synthesis of water from the constituent elements<br />
(continuous combustion, the inverse of<br />
water electrolysis)<br />
· Synthesis of HCI from the constituent elements<br />
667 403<br />
74 LEYBOLD DIDACTIC · GENERAL CATALOGUE CHEMISTRY<br />
Equipment list<br />
Combustion chamber with incandescent wire<br />
The chamber is equipped with a platinum filament<br />
which is heated electrically to the point at<br />
which it glows. The chamber is connected by<br />
two GL 18 screw thread connectors to two<br />
gas syringes from which the gases are introduced<br />
under slight pressure. The electrical heating<br />
of the platinum coil allows for simple, nonhazardous<br />
generation of elevated temperatures.<br />
Reverse reactions are largely inhibited<br />
since the area inside the combustion chamber<br />
itself remains cold.<br />
Application examples<br />
· Dissociation of butane into its constituent elements<br />
· Elementary organic analysis and detection of<br />
oxygen in organic compounds, using dimethyl<br />
ether as an example<br />
· Model experiments for a thermal conductivity<br />
detector<br />
Butane gas analysis by thermal decomposition<br />
Combustion chambers<br />
All the combustion chambers supplied by<br />
LEYBOLD DIDACTIC are made of glass. They<br />
have GL 18 screw thread connectors at both ends<br />
for connecting gas syringes. The platinum wires,<br />
fused into the glass, are given additional protection<br />
against detachment with the lateral supports.<br />
The entire course of the experiment remains<br />
transparent -in the truest sense of the word<br />
Advantages:<br />
· Quick and easy setup on the laboratory stand<br />
· Quantitative statements regarding<br />
volumetric ratios are possible<br />
· Non-corroding platinum electrodes and coils<br />
· Platinum pins cannot break away from<br />
their attachments<br />
Quantity Description Cat. No.<br />
1 Combustion chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667 403<br />
1 Gas syringe, 100 ml . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665 912<br />
1 Gas syringe with 3-way stopcock,100 ml . . . . . . . . . . . . . . 665 914<br />
2 Gas syringe holder 100 ml . . . . . . . . . . . . . . . . . . . . . . . . . . 665 918<br />
1 Variable extra low voltage transformer D . . . . . . . . . . . . . . . 667 827<br />
1 Pair of cables, 1 m, red and blue . . . . . . . . . . . . . . . . . . . . 501 46<br />
2 Set of 6 croc-clips, polished. . . . . . . . . . . . . . . . . . . . . . . . . 501 861<br />
1 MINICAN gas can: n-Butane . . . . . . . . . . . . . . . . . . . . . . . . 660 989<br />
1 Fine regulating valve MINICAN for gas cans. . . . . . . . . . . . . 660 980<br />
1 Submerged-coil manometer after Schiele . . . . . . . . . . . . . . 665 936<br />
1 Base rail, 95 cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 603<br />
2 Stand tube, 450 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 609<br />
2 Universal bosshead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 615<br />
4 Bosshead S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 09<br />
1 Universal clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 555<br />
1 Universal clamp, 0 ... 120 mm . . . . . . . . . . . . . . . . . . . . . . . 301 72<br />
1 PVC tubing, 5 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667 191<br />
667 818<br />
Spark gap supply unit<br />
Current-limited to 2 mA, thus no contact<br />
hazard according to VDE 0105; for generating<br />
a brief ignition spark or a constant spark gap<br />
with contact-safe high-voltage sockets and<br />
additional ground socket.<br />
Mains connection: 230 V, 50 Hz<br />
Output: DC, approx. 10,000 V/2.0 mA<br />
Dimensions: 20 x 14 x 23 cm<br />
Weight: 3.0 kg<br />
Scope of delivery<br />
1 Pair of connecting leads 50 cm,<br />
1 Pair tapping terminals,<br />