General Catalogue Chemistry - BECO Internacional LTDA.
General Catalogue Chemistry - BECO Internacional LTDA.
General Catalogue Chemistry - BECO Internacional LTDA.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Conductiometric titration<br />
In a neutralization reaction, the conductivity initially decreases, as virtually<br />
undissociated water is formed. Conductivity subsequently increases due to a<br />
surplus of titrant. The point of lowest conductivity corresponds to the equivalence<br />
point of the titration. Precipitation and complexometric titrations<br />
can also be conducted in a similar manner.<br />
Equipment list<br />
Conductiometric titration<br />
Quantity Description Cat. No.<br />
1 Digital conductivity meter . . . . . . . . . . . . . . . . . . . . . . . . . . . 667 439<br />
1 Conductivity measurement cell . . . . . . . . . . . . . . . . . . . . . . 667 426<br />
1 Magnetic stirrer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 845<br />
1 Stand rod for Bunsen stand . . . . . . . . . . . . . . . . . . . . . . . . . 666 523<br />
1 Bosshead S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 09<br />
1 Miniature clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 551<br />
1 Burette clamp for one burette . . . . . . . . . . . . . . . . . . . . . . . 666 559<br />
1 Burette, 25 ml. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665 845<br />
1 Beaker, 250 ml. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664 103<br />
667 426<br />
Conductivity measurement cell<br />
In plastic holster with cable and plug for connection<br />
to the conductivity box (> 524 037)<br />
Cell constant 1.0 1/cm<br />
666 214<br />
Temperature sensor, Pt 100<br />
For use in connection with instruments<br />
> 667 420 and > 666 450 for temperature<br />
compnsation in connction with > 667 439<br />
and > 666 451. Pt 100 resistent element,<br />
with connection cable and DIN connector.<br />
><br />
666 222<br />
Data output module<br />
see page 636<br />
Hand-held conductivity meter<br />
For measuring the conductivity (conductance)<br />
of solutions and Temperatures.<br />
Detailed description see page 5.<br />
666 212<br />
Temperature sensor<br />
NTC resistance element for more precise. measurement.<br />
With coiled cord (1.5 m) and DIN plug.<br />
Measurement range: - 20 to + 120 °C<br />
Tolerances:<br />
- 20 to + 70 °C: 0.2 K<br />
+ 70 to + 120 °C: 0.4 K<br />
Diameter: 3 mm<br />
Overall length: 280 mm<br />
667 4101<br />
Watercheck pH and conductivity tester<br />
Combination meter for pH and conductivity.<br />
With single-point calibration and automatic<br />
temperature compensation for conductivity,<br />
rapid response time.<br />
Measuring range:<br />
0.0 to 14.0 pH, 0 to 1999 µS/cm<br />
Resolution: 0.1 pH, 10 µS/cm<br />
Accuracy (20 °C): ± 0.2 pH/±2 %<br />
Calibration: single-point via trimmer<br />
Temperature compensation:<br />
automatic for conductivity<br />
Ambient conditions: 0 to 50 °C, RH 95 %<br />
Battery (included): 3 x 1.5 V/approx. 290 h<br />
Dimensions: 194 x 29 x 165 mm<br />
Weight: 70 g<br />
667 4101<br />
measuring equipment - conductivity<br />
667 4272<br />
Conductivity tester DiST 3<br />
With integrated temperature sensor for automatic<br />
temperature compensation and manual<br />
calibration option.<br />
Complete with protective cap and batteries.<br />
Measuring range 1999 µS/cm<br />
Resolution: 1 µS/cm<br />
Accuracy (20 °C): ±1 %<br />
Calibration: manual via trimmer<br />
Temperature compensation:<br />
automatic from 5 to 50 °C<br />
Ambient conditions: 0 to 50 °C, RH 95 %,<br />
RH 100% waterproof version<br />
Battery: 4 x 1.5 V/approx. 350 h<br />
Dimensions: 150 x 30 x 24 mm<br />
Weight: 85<br />
667 4271<br />
Conductivity tester DiSTWP 3<br />
Waterproof.<br />
667 4271<br />
LEYBOLD DIDACTIC · GENERAL CATALOGUE CHEMISTRY<br />
201