05.12.2012 Views

General Catalogue Chemistry - BECO Internacional LTDA.

General Catalogue Chemistry - BECO Internacional LTDA.

General Catalogue Chemistry - BECO Internacional LTDA.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

665 509<br />

Flatbed electrophoresis chamber “SepBloc”<br />

Especially for electrophoretic separations of<br />

proteins in connection with non-toxic agarose<br />

gels. Production of the gels is straightforward<br />

and is run directly in the separation chamber.<br />

The voltage is applied via high tension safety<br />

sockets.<br />

The safety leads which are required are<br />

included.<br />

Max. operating voltage: 300 V DC<br />

Max. current: 100 mA<br />

Dimensions: 180 x 120 x 60 mm<br />

Weight: 0.95 kg<br />

661 109<br />

Set of chemicals for electrophoresis<br />

For production of agarose gels in the “Sep-<br />

Bloc” separating chamber (> 665 509) and<br />

for the experiments described in the manual<br />

(> 668 371).<br />

Scope of delivery<br />

150 µg Antibody, goat, in 150 µg 1 x SDS<br />

sample buffer<br />

10 ml �-mercaptoethanol<br />

10 ml Bromophenol blue (0.1 %)<br />

500 mg Coomassie brilliant blue<br />

250 ml Acetic acid, conc.<br />

50 ml Glycerine<br />

50 g Glycine<br />

500 µg Lysozyme in 50 µl 1 x SDS samplebuffer<br />

200 µl Marker protein, 40 µl filled to 200 µl<br />

with 1 x SDS sample buffer<br />

1000 ml Methanol<br />

50 µg Ovalbumin, goat, in 50 µl<br />

1 x SDS sample buffer<br />

30 ml Collecting agarose<br />

200 µg Serum, goat, in 50 µl 2 x SDS<br />

sample buffers<br />

120 µg Serum albumin, goat, in 120 µl 1 SDS<br />

sample buffer<br />

25 ml Sodium duodecylsulphate solution<br />

(10 % w/v)<br />

120 ml Separating agarose<br />

10 g Tris base<br />

5 ml 0.5 M tris HCI pH 6.8<br />

Additionally required:<br />

Dried yeast<br />

665 509 665 635<br />

667 821<br />

667 821<br />

Electrophoresis power supply unit<br />

For supplying power to the flatbed electrophoresis<br />

chamber (> 665 509). The output voltage<br />

is electrically isolated from the mains and may<br />

be tapped off at high tension safety sockets.<br />

The output is continuously variable and a pointer-type<br />

meter is provided. Complete with mains<br />

cable.<br />

Output voltage: 270 V DC<br />

Output current:<br />

40 mA max., continuously variable<br />

Meter: 0 ... 1000 mA, pointer type<br />

Fuses: sec.: T 0.1 A, pri.: M 0.1 A<br />

Power consumption: 25 W<br />

Mains supply voltage: 230 V, 50/60 Hz<br />

Dimensions: 220 x 140 x 150 mm<br />

Weight: 1.3 kg<br />

665 635<br />

Analysis lamp<br />

analysis methods<br />

For short- and long-wave UV radiation, for<br />

examination of the fluorescent properties of<br />

many inorganic and organic substances and in<br />

chromatography to differentiate among oils,<br />

dyes, minerals, nutrients, textiles etc. on the<br />

basis of their fluorescent colour.<br />

Wavelengths: 254 nm and 366 nm<br />

Power: 4 watts each<br />

Power supply: 230 V, 50 Hz<br />

Dimensions: 205 x 70 x 55 mm<br />

Weight: 1.0 kg<br />

665 634<br />

Stand<br />

For analysis lamp (> 665 635)<br />

Dimensions: 110 x 230 x 240 mm<br />

Weight: 1.0 kg<br />

665 510<br />

Pipetting kit<br />

for set of chemicals for electrophoresis<br />

Scope of delivery<br />

1 Pipetting aid (graduated) 0.5 -125 ul<br />

100 pipetting tips<br />

(with volume measuring tabel)<br />

100 self-supporting reaction vessels<br />

30 srew-on caps for reaction vessels<br />

LEYBOLD DIDACTIC · GENERAL CATALOGUE CHEMISTRY<br />

67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!