05.12.2012 Views

General Catalogue Chemistry - BECO Internacional LTDA.

General Catalogue Chemistry - BECO Internacional LTDA.

General Catalogue Chemistry - BECO Internacional LTDA.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

664 431<br />

Solar cells<br />

Generates electrical current from the sun's<br />

energy. The two solar cells are mounted on a<br />

rotating shaft, making it possible to adjust them<br />

for varying angles of incidence to the sun's<br />

light. The two cell arrays may be connected in<br />

parallel (for higher current) or in series (for higher<br />

voltage). The voltage is available at the<br />

sockets on the base plate.<br />

Angle of inclination: 0 ... 90°<br />

Dimensions: 25 cm x 16 cm x 25 cm<br />

Weight: 1.6 kg<br />

Light intensity [k|x] U max [V] I max [mA]<br />

10 5.1 70<br />

20 5.4 150<br />

30 5.4 300<br />

50 5.7 400<br />

664 430<br />

Windmill<br />

Generates electrical current when turned by<br />

wind energy. The air flow can be generated by<br />

a blower. The voltage thus generated is available<br />

at two sockets on the base of the stand.<br />

The windmill can also be operated as a motor<br />

(in conjunction with the solar cell > 664 431,<br />

for example). Wind generation by a blower<br />

(> 666 735, for example); distance between<br />

blower and windmill: 250 mm.<br />

Windmill operation<br />

U max : 3 V<br />

I max : 70 mA<br />

Motor operation<br />

U max : 12 V<br />

Dimensions: 28 cm x 1 cm x 12.5 cm<br />

Weight: 630 g<br />

664 432<br />

Electrolysis cell<br />

electrochemistry<br />

For producing hydrogen (and oxygen) by applying<br />

electric current. The electrolysis cell is of a<br />

very compact design and is attached to the<br />

stand with spring clamps. The platinum electrodes<br />

are mounted in the glass section by<br />

means of threaded connectors to reduce the<br />

risk of breakage. The electrolysis cells may also<br />

be used as a water electrolysis unit after<br />

Hofmann. The required electrical energy can be<br />

supplied either from a power supply unit<br />

(> 667 826, for example), the solar cell<br />

(> 664 431) or the windmill (> 664 430 ).<br />

Operating voltage: >2 V<br />

Uop: 3 V I = 70 mA approx.<br />

Uop: 4 V I = 170 mA approx.<br />

Uop: 5 V I = 340 mA approx.<br />

Dimensions: 450 x 160 x 250 mm<br />

Weight: 2.3 kg<br />

LEYBOLD DIDACTIC · GENERAL CATALOGUE CHEMISTRY<br />

39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!